Indirect Sensitive Determination of Oxymetazoline. HCl in Pure Pharmaceutical Drugs and Biological Samples Using a Modified Sensor Unit Via a Green Method of FI/MZ System
محل انتشار: نشریه متدهای شیمیایی، دوره: 7، شماره: 1
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 143
فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_CHM-7-1_007
تاریخ نمایه سازی: 19 مهر 1401
چکیده مقاله:
A new FI method was examined with many advantages such as simplicity, high sensitivity and accuracy, economical in terms of material consumption, environmentally friendly, and less hazardous to laboratory with the minimum volume of reactants. Flow injection analysis is a process employ for estimation of Oxymetazoline hydrochloride in pharmaceutical forms by spectrophotometric with merging zone technology. This method depends on the oxidation-reduction reaction a cross the oxidizing agent the drug while reducing it to iron(II). The reduced form reacts with the reagent ۲,۲`-bipyridyl to give a pink complex is measured at λmax (۵۲۱) nm. Linear calibration curve obeyed Beer's law ۱۰-۵۰۰ μg.mL-۱ with detection limit ۶.۱۹۵ μg.mL-۱ for the developed FIA method. The velocity of sampling was ۷۲ sample.h-۱, the RSD was ۲.۷۱۶%, and the average recovery was ۱۰۱%. By using distilled water as a carrier of chemicals with this analytical technique, it is less dangerous and less polluted. The suggested method was effectively used to estimate OXY in medicinal drugs and biological materials. The obtained results were statistically treated and comparable to the official method (British Pharmacopeia).A new FI method was examined with many advantages such as simplicity, high sensitivity and accuracy, economical in terms of material consumption, environmentally friendly, and less hazardous to laboratory with the minimum volume of reactants. Flow injection analysis is a process employ for estimation of Oxymetazoline hydrochloride in pharmaceutical forms by spectrophotometric with merging zone technology. This method depends on the oxidation-reduction reaction a cross the oxidizing agent the drug while reducing it to iron(II). The reduced form reacts with the reagent ۲,۲`-bipyridyl to give a pink complex is measured at λmax (۵۲۱) nm. Linear calibration curve obeyed Beer's law ۱۰-۵۰۰ μg.mL-۱ with detection limit ۶.۱۹۵ μg.mL-۱ for the developed FIA method. The velocity of sampling was ۷۲ sample.h-۱, the RSD was ۲.۷۱۶%, and the average recovery was ۱۰۱%. By using distilled water as a carrier of chemicals with this analytical technique, it is less dangerous and less polluted. The suggested method was effectively used to estimate OXY in medicinal drugs and biological materials. The obtained results were statistically treated and comparable to the official method (British Pharmacopeia).
کلیدواژه ها:
FI/MZ Oxymetazoline.HCl Green chemistry ۲ ، ۲`-bipyridyl Biological samples Pharmaceutics
نویسندگان
Shahad L. Hamed
Department of Chemistry, College of Science, University of Baghdad, Baghdad, Iraq
Bushra B. Qassim
Department of Chemistry, College of Science, University of Baghdad, Baghdad, Iraq
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :