Design, Implementation and Comparison of Two Wavelet Based Methods for the Detection of Broken Rotor Bars in Three Phase Induction Motors
سال انتشار: 1388
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,195
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
PEDSTC01_062
تاریخ نمایه سازی: 21 تیر 1391
چکیده مقاله:
Preventive maintenance of induction motors has an important role in reducing expensive shutdowns due to motor faults. Motor Current Signature Analysis, MCSA, provides a simple way to evaluate the health of a machine. In this paper, two different wavelet based methods are proposed to detect broken rotor bar faults in three phase induction motors. The methods are in addition examined on laboratory experimental data where broken rotor bars are detected successfully. Moreover, the proposed criteria are compared in different aspects like the correlation between them and fault level, their computational load and their ability of differentiation between healthy condition and other faulty conditions. Finally one of the proposed methods is suggested for implementation in future systems.
کلیدواژه ها:
Induction Motor ، Fault Detection ، Broken Rotor Bars ، Discrete Wavelet Transform ، Root Mean Square (RMS) ، Variance
نویسندگان
Salehi Arashloo
Dept. of Elec. Eng., Centre of Excellence for Power Systems Automation and Operation University of Science & Technology Iran
Jalilian
Dept. of Elec. Eng., Centre of Excellence for Power Systems Automation and Operation University of Science & Technology Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :