The Effects of the Thermo-Mechanical Process Variables on the Microstructure, Mechanical Properties, and Recrystallization Behavior of the Commercially Pure Titanium
محل انتشار: مجله شکل دهی مواد، دوره: 9، شماره: 3
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 155
فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMF-9-3_002
تاریخ نمایه سازی: 9 مرداد 1401
چکیده مقاله:
Commercial pure titanium sheets were thermo-mechanically treated to investigate the effects of the treatment variables on the microstructure, mechanical properties, and recrystallization behavior. The as-received sheets were initially cold-rolled up to different reduction percentages of ۶۰%, ۷۵%, and ۹۰%. Then, the cold-rolled samples were annealed at different temperatures of ۵۰۰°C-۷۰۰°C, for various time ranges of ۵ to ۶۰ minutes. The evolution of the microstructure of the samples was studied using X-ray diffraction analysis and optical microscopy. The hardness of the ۹۰% cold-rolled sample was about ۸۲% higher than that of the as-received sheet. Increasing the time and temperature of the annealing process caused a decrease in the microhardness values of the samples. The recrystallization activation energy and Avrami’s exponent of the ۹۰% cold-rolled sample were calculated as about ۱۷۹ kJ/mol and ۰.۷۵, respectively. The results of the uniaxial tensile tests revealed that the cold-rolling process significantly improved the yield strength (YS) and ultimate tensile strength (UTS) of the specimens. In the case of the ۹۰% cold-rolled sample, these values improved by about ۱۶۰% and ۱۱۷% with respect to the as-received metal, respectively. However, the elongation of the cold-rolled samples dropped sharply. Moreover, annealing had a positive effect on the elongation of the cold-rolled samples. The UTS and elongation percentage of the as-received sheet were ۴۱۵ MPa and ۳۶.۴%, respectively. These values were varied to ۵۵۸ MPa and ۲۹.۱۵% for the ۹۰% cold-rolled sample annealed at ۷۰۰°C for ۱ h. To study the fracture behavior of the different samples, scanning electron microscopy (SEM) was used.
کلیدواژه ها:
نویسندگان
Y. Mazaheri
Department of Materials Science and Engineering, School of Engineering, Shiraz University, Shiraz, ۷۱۹۴۶-۸۴۳۳۴, Iran
K. Ahmadi
Department of Materials Engineering, Bu-Ali Sina University, Hamedan, ۶۵۱۷۸-۳۸۶۹۵, Iran
M.M. Jalilvand
Department of Materials Engineering, Bu-Ali Sina University, Hamedan, ۶۵۱۷۸-۳۸۶۹۵, Iran
M. Bahiraei
Department of Materials Engineering, Bu-Ali Sina University, Hamedan, ۶۵۱۷۸-۳۸۶۹۵, Iran
M. Sheikhi
Department of Materials Engineering, Bu-Ali Sina University, Hamedan, ۶۵۱۷۸-۳۸۶۹۵, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :