Numerical Study of the L/D Ratio and Turbulent Prandtl Number Effect on Energy Separation in a Counter-Flow Vortex Tube
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 139
فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JAFM-15-5_017
تاریخ نمایه سازی: 13 تیر 1401
چکیده مقاله:
Vortex tube is a device without moving parts with ability to separate pressurized gas into two streams: cold and hot. This is a consequence of the Eckert-Wiese effect, which is responsible for spontaneous redistribution of total energy within the flow domain. In order for vortex tubes to work properly, there are some constraints which have to be fulfilled. The most important constraint in that sense is the L/D ratio. One part of this paper is dedicated to the research of the influence of L/D ratio on the energy separation in a vortex tube, i.e. to the values of total temperatures on cold and hot outlets of the device. On the other hand, experimental research of the inner flow is quite challenging since vortex tube is a device of small dimensions. Hence, we are relaying on numerical computations. One of important quantities that has to be prescribed in these computations is the turbulent Prandtl number PrT. Because of that, the other part of this paper is dedicated to research of the influence of PrT on the results of numerical computations. The research is conducted using open-source software OpenFOAM. Turbulence is modelled using two-equation and RST models. For small L/D ratios there is a secondary circulation that acts as a refrigeration cycle, and for greater L/D ratios distribution of velocity and temperature inside the vortex tube remains the same, regardless of the stagnation point presence. It is not justified to increase the length of the vortex tube beyond ۲۰D since the change in cold total temperature inside the vortex tube as well at the cold outlet is practically null. For L/D variation from ۱.۸ to ۱۰, the cold outlet temperature changes from ۲۷۰.۹ K to ۲۶۶.۸ K, and then rises to its final value of ۲۷۰.۵ K. For L/D ratio from ۲۰ to ۶۰, the total temperature at cold end remains unchanged at ۲۷۱.۳ K. We obtained good results with the unit value of turbulent Prandtl number, and demonstrated that increasing the PrT beyond unit value is not necessary in order to numerically obtain the energy separation inside the vortex tube.
کلیدواژه ها:
نویسندگان
J. Burazer
University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije ۱۶, ۱۱۱۲۰ Belgrade ۳۵, Serbia
D. Novkovic
University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije ۱۶, ۱۱۱۲۰ Belgrade ۳۵, Serbia
A. Cocic
University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije ۱۶, ۱۱۱۲۰ Belgrade ۳۵, Serbia
M. Bukurov
University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića ۶, ۲۱۱۰۲ Novi Sad, Serbia
M. Lecic
University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije ۱۶, ۱۱۱۲۰ Belgrade ۳۵, Serbia
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :