A three-year survey of film badge service performance in Iran
محل انتشار: مجله پزشکی هسته ای ایران، دوره: 3، شماره: 1
سال انتشار: 1374
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 250
فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJNM-3-1_003
تاریخ نمایه سازی: 7 تیر 1401
چکیده مقاله:
An extensive study was undertaken to Investigate on the overall film badge service performance with which occupational radiation, exposures are reported In Iran, The study involved the analysis of film badges exposed to x-and gamma rays and beta particles. For test exposures, x-rays between ۶۰ and ۱۴۰ KVPCo-۶۰ gamma radiation and Sr-۹۰ beta particles were used. The actual delivered dose equivalents were limited to ۰.۴۰-۵ mSv which is the range of annual occupational dose reported by many international studies. This study revealed that the reporting on gamma rays, specially for Co-۶۰, was very good. The reports on x-rays were overestimated. The overestimation was considerable at higher kVp's. The results for beta particles were rather poor.
کلیدواژه ها:
نویسندگان
H Mohammadi
Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran
S Mehdizadeh
Radiation Center, Shiraz University, Shiraz, Iran
Sh Derakhshan
Radiation Center, Shiraz University, Shiraz, Iran