Reliability of Center of Pressure measures of Postural Stability in Anterior Cruciate Ligament Reconstructed Athletes: Effect of Vibration and Cognitive Load

سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 278

فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_TABO-10-2_007

تاریخ نمایه سازی: 19 بهمن 1400

چکیده مقاله:

Background: To evaluate intra and intersession reliability of the Center of Pressure (COP) parameters in AnteriorCruciate Ligament Reconstructed (ACLR) athletes with and without ankle vibration using a dual-task paradigm.Methods: Postural sway of ۱۴ ACLR individuals was assessed during a single-leg stance on a force platform. COPparameters were assessed with manipulating sensory inputs via vision and ankle vibration under single and dual-taskconditions. The outcome variables included COP displacement in medial-lateral (ML) and anterior-posterior (AP) range,mean velocity (mV), and area. During dual-task conditions, the auditory Stroop Task was applied. Intraclass correlationcoefficient (ICC) values and standard error of measurement (SEM) were assessed for relative and absolute reliability.Results: The COP measures had moderate to very high intrasession reliability (ICC range: ۰.۵۱-۰.۹۳) for conditionswith vibration and cognitive task, with the highest ICCs for mV and the lowest for area, regardless of eyes being openor closed. The intersession reliability was moderate to high for mV (ICC range: ۰.۶۰-۰.۸۲) and little to very high (ICCrange: ۰.۲۱-۰.۹۷) for the range of ML and AP, as well as an area in conditions with vibration and cognitive task.Conclusion: The mV is the most reliable COP parameter for assessing postural control under ankle vibration and dualtaskconditions for both operated and non-operated sides. During closed-eye conditions, the application of vibrationaffected the intersession reliability with decreased ICCs on the operated side and increased ICCs on the non-operatedside.Level of evidence: III

کلیدواژه ها:

Anterior cruciate ligament reconstruction ، Postural control ، Stroop Task ، Test-retest reliability ، Vibration

نویسندگان

Shahrzad Mohammadi-Rad

Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

Mohammad Mohseni Bandpei

Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

Mahyar Salavati

Department of Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

Saeed Talebian

Department of Physical Therapy, School of Rehabilitation Sciences, Tehran University of Medical Sciences, Tehran, Iran

Sohrab Keyhani

Akhtar Hospital, Shahid Beheshti University of Medical Science, Tehran, Iran

Sanaz Shanbehzadeh

Rehabilitation Research Center, Iran University of Medical Science, Tehran, Iran