Effect of Collars and Bars in Reducing the Local Scour Around Cylindrical Bridge Piers
محل انتشار: ماهنامه بین المللی مهندسی، دوره: 22، شماره: 4
سال انتشار: 1388
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 186
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJE-22-4_002
تاریخ نمایه سازی: 18 بهمن 1400
چکیده مقاله:
In the present work, the efficiency of single and double collar in reducing scour rate and depth around cylindrical bridge piers was studied experimentally. In order to reduce the strength of wake vortices, different numbers of bars were also installed at the downstream face of the pier in combination with a single collar. The best result was achieved for double collar when the collars were installed at the streambed level and one pier diameter below bed level. With this arrangement the lower collar was not undermined after ۸۰ hours of experiment, showing about ۵۶ % reduction in scouring compared with an unprotected pier. It was also shown that by using collars, the rate of scouring decreased considerably. Though installation of bars did not significantly reduce the maximum depth of scour, it postponed the beginning of scouring at the upstream face of the pier.
کلیدواژه ها:
نویسندگان
Mohammad Javad Rezaei
Civil & Environmental Engineering, Amir Kabir University of Technology
A.R. Zarrati
Civil & Environmental Engineering, Amirkabir University of Technology (Tehran Polytec
Mohammad B. Mashahir
Civil & Environmental Engineering, Amir Kabir University of Technology
Masood Zokaei
Civil & Environmental Engineering, Amir Kabir University of Technology