Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
محل انتشار: مجله استخوان و جراحی عمومی، دوره: 3، شماره: 1
سال انتشار: 1394
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 180
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_TABO-3-1_007
تاریخ نمایه سازی: 11 بهمن 1400
چکیده مقاله:
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compare its biomechanical features with conventional absorbable interference screw technique in a bovine model. Methods: Twenty pairs of bovine knees were harvested after death. Soft tissue was removed and the Achilles tendon was harvested to be used as an ACL graft. It was secured into the bone tunnel on the tibial side via two different methods: Bashti Bone Plug technique and conventional screw method. Biomechanical strength was measured using ۲۰۰ N and ۳۰۰ N cyclic loading on the graft. Pull out strength was also tested until the graft fails. Results: No graft failure was observed after ۲۰۰ N and ۳۰۰ N cyclic loading in either fixation methods. When testing for pull out failure, ۲۱ tendons (۵۳%) were torn and ۱۹ tendons (۴۸%) slipped out. No fixation failure occurred, which did not reveal a significant difference between the bone plug or interference screw group (P=۰.۱۱). The mean pull out force until failure of the graft was ۴۹۶±۶۶ N in the screw group and ۵۰۳±۶۷ N in the bone plug group (P=۰.۷۶). Conclusions: Our suggested fixation technique of Bashti bone plug is a native, cheap, and feasible method that provides comparable biomechanical strength with interference screw when soft tissue fixation was attempted in bovine model.
کلیدواژه ها:
نویسندگان
Kaveh Bashti
Tehran university of medical sciences
Mohammad Naghi Tahmasebi
Tehran university of medical sciences,Shariati hospital
Hasan Kaseb
Tehran university of medical sciences,Emam hospital
Farzam Farahmand
Sharif university of technology.School of biomechanics
Mohammad Akbar
Sharif university of technology,school of biomechanics
Amir Mobini
Sharif university of technology, school of bimechanics
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :