The Performance of Self-Compacted High Strength ConcreteColumns with Laced Steel Section

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: فارسی
مشاهده: 126

فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_CEJ-4-11_008

تاریخ نمایه سازی: 28 آذر 1400

چکیده مقاله:

In view of the great orientation to the steel buildings and the large role played by the columns in carrying and transferring the loads it is necessary to go to strengthen the steel rolled columns to meet the requirements of the architecture that witch is looking for large spacing. In present paper this research the objectives of this research can be summarized as following: prevent local buckling occurs in columns, strengthen the steel columns from the weak axis in a new methodology, to compare buckling loads of single lacing reinforcement versus double lacing reinforcement and obtain a high bearing column steel section with small surface area increase in column strength capacity. Different parameters are taking into account to investigate the behavior and strength of steel and composite columns such as slenderness ratio, and double lacings and presence of longitudinal reinforcement that parallel to the column height. The type of concrete that adopt is self-compact concrete with high compressive strength. The new and alternative method is were used to strengthen the steel rolled columns at low cost by strengthening the weak axis to preventing or minimize buckling of the columns by using high strength concrete self-compacted without main reinforcements with steel section columns reinforced by lacing as single and double so that it work as full composite structural element and there are connections between concrete block and steel column. There are five specimens with the same height of ۱۴۵۰ mm that was classified as the control specimen and the others with different parameters such as lacing configurations, presence of longitudinal dowels and presence of concrete subject to concentric load. All specimens except the control filled with self-compacted high strength concrete. The result showed that as increase in strength in presence of concrete as compared with the control specimen. Control specimen gave strength capacity compared with the others composite specimens; the increased are ۵۰% composite column, ۶۲.۵۰% composite column with single lacing and ۷۵.۰۰% composite column with double lacing respectively. Specimen (CL۱CDL۲R) increased in strength capacity as compared with the control specimen ۸۷.۵۰% and ۷.۱۴% compared with specimen (CL۱CDL) because of presence dowels along the specimen height that increase the stiffness of the composite column. Presence of single and double lacing reduced the buckling value because of reduced the effective columns height. Specimen (CC۱L۱) gave maximum buckling ۳۲.۰۰ mm compared with the others specimens such as CL۱C), (CL۱CSL), (CL۱CDL) and (CL۱CDL۲R) respectively, there is significant difference in buckling that reduced by ۱۷.۱۹%, ۲۸.۱۳%, ۴۵.۳۱% and ۵۵.۶۳% respectively.

نویسندگان

Anas Hameed Majeet

aUniversity of Baghdad, College of Engineering, Department of Civil Engineering, Baghdad, Iraq

Ahmad Jabbar Hussain Alshimmeri

aUniversity of Baghdad, College of Engineering, Department of Civil Engineering, Baghdad, Iraq