Removal of Hexavalent Chromium from Aqueous Solutions Using Magnetic Nanoparticles Coated with Alumina and Modified by Cetyl Trimethyl Ammonium Bromide
محل انتشار: فصلنامه تخصصی تحقیقات سلامت، دوره: 4، شماره: 3
سال انتشار: 1394
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 239
فایل این مقاله در 17 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JCHR-4-3_003
تاریخ نمایه سازی: 11 مهر 1400
چکیده مقاله:
Introduction: The development of an effective method regarding chromium removal from the environment is of great importance. Therefore, the present study aimed to examiner magnetic nanoparticles coated with alumina modified by Cetyl Trimethyl Ammonium Bromide (CTAB) in the removal of Cr۶+ through magnetic solid phase extraction method.
Materials & Methods: At first, iron oxide nanoparticles were synthesized, coated with alumina, modified with CTAB and characterized with suitable instruments. The factors affecting the process of chromium removal were investigated, including the concentration of CTAB, the pH, the amount of nanoparticles, the sample volume, a proper eluent, the adsorption and desorption time, and the effect of interfering ions. Moreover, the chromium concentration was determined by flame atomic absorption spectrometric (FAAS) technique. The adsorption isotherm, adsorption capacity, and recoverability of the adsorbent were further examined.
Results: The modified magnetic nanoparticles were demonstrated to be homogeneous, spherical, with a size lower than ۲۰ nanometer having a magnetic property. The optimal conditions for chromium removal entailed ۷*۱۰-۶ mol/L concentration of CTAB, pH range of ۶-۸, ۰.۱ g of the nanoparticles, ۱۰ mL volume of the chromium sample (۵ &mug mL-۱), nitric acid ۲ M as a suitable eluent, ۱۵ minutes of adsorption and desorption, and no interference of interfering ions in the process of chromium separation. The process efficiency under optimal conditions was determined to be over ۹۵%, which this process followed the Langmuir adsorption isotherm. The adsorption capacity proved to be ۲۳.۸ mg/g. Reusing after four times of adsorbent recovering was effective in the chromium removal (۸۰%). The method accuracy for five measurement times was ۴.۱۵۵% and the method’s LOD was ۰.۰۸۱ mg/L.
Conclusion: The method enjoys the benefits of convenient preparation of the adsorbent, high selectivity, high accuracy, short process time, and high-efficiency in chromium removal from aquatic environments, lending itself to be used in the real samples.
کلیدواژه ها:
Hexavalent chromium ، Magnetic solid phase extraction ، Magnetic nanoparticles ، Cationic surfactant ، کروم شش ظرفیتی ، استخراج فاز جامد مغناطیسی ، نانوذرات مغناطیسی ، سورفاکتانت کاتیونی
نویسندگان
محمد ملکوتیان
Environmental Health Engineering Research Center and Department of Environmental Health, Kerman University of Medical Sciences, Kerman, Iran
اصغر عسکرپور
Department of Chemistry & Nanoscience and Nanotechnology Research Laboratory, Payame Noor University of Sirjan, Kerman, Iran
نجمه امیرماهانی
Environmental Health Engineering Research Center, Kerman University of Medical Sciences, Kerman, Iran
زهرا نصیری
Fatemeh Alzahra Department, Organization of Education, Kerman, Iran
علیرضا نصیری
Environmental Health Engineering Research Center, Kerman University of Medical Sciences, Kerman, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :