Glomerular Filtration Rate Estimation Based on Cystatin C Formulas among Neonates
محل انتشار: مجله علمی ناباروری ایران، دوره: 12، شماره: 2
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 146
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJN-12-2_004
تاریخ نمایه سازی: 18 اردیبهشت 1400
چکیده مقاله:
Background: Glomerular filtration rate (GFR) is the best indicator to assess renal function; however, it is difficult to perform it, especially in neonates. Serum creatinine is the most commonly used marker of GFR; nevertheless, it has some limitations since it can be affected by factors other than renal function. Cystatin C, another endogenous marker used to estimate GFR, is not affected by non-renal factors. The results of some studies suggest that serum cystatin C levels are more accurate tests of kidney function than serum creatinine levels. This study aimed to estimate GFR with cystatin C-based formulas among neonates and determine the correlations between these methods and the Schwartz formula. Methods: The population of this research consisted of ۹۹ neonates whose serum creatinine and cystatin C levels were measured concurrently. Moreover, the glomerular filtration rate was estimated using the Schwartz formula and ۱۴ cystatin C-based formulas separately. Results: Based on the findings, all GFR values based on cystatin C formulas correlated significantly with each other (p <۰.۰۵); however, with one exception, none of these values correlated with Schwartz GFR (P>۰.۰۵). The only cystatin C formula that yielded values correlating with the Schwartz formula was CysCrEq, which used serum cystatin C and creatinine concomitantly. Conclusion: It can be concluded that since all GFR values based on cystatin C correlated significantly and cystatin Cwasindependent of non-renal factors, cystatin C reflected the real GFR more accurately than serum creatinine. Nonetheless, further studies with gold standard techniques are required to verify the usefulness of cystatin C-based formulas.
کلیدواژه ها:
نویسندگان
- -
Iran University of Medical Sciences, Tehran, Iran
- -
Student Research Committee, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
- -
Iran University of Medical Sciences, Tehran, Iran
- -
Iran University of Medical Sciences, Tehran, Iran
- -
Iran University of Medical Sciences, Tehran, Iran
- -
Iran University of Medical Sciences, Tehran, Iran
- -
Iran University of Medical Sciences, Tehran, Iran
- -
Iran University of Medical Sciences, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :