چکیده مقاله:

One of the popular orthopedic implants is utilizing fixation screws to fix Anterior Cruciate Ligament (ACL) grafts and secure the graft into femur and tibia. Currently, these screws are made of titanium or bioabsorbable materials. In this respect, bioabsorbable screws were generated in order to overcome some of the potential problems caused by metallic screws. Although the bioabsorbable screws are susceptible to some drawbacks includingbone ingrowth features as well as good in vitro and in vivo mechanical properties. The biomechanical results of ACL screws showed that the ultimate failure loads and yield point loads varied from 800-1500 N and 600-1000 N, respectively. Moreover, the evaluations of in vivo degradation behaviorshowed the almost complete or fully complete resorption of ACL screws from 6 month to 2 years. However, it was proved that the addition of bone mineral phases such as Hydroxyapatite (HA), β-Tricalcium Phosphate (β-TCP), and Calcium Carbonate (CC) could enhance this degradation rate. Incorporation of biceramics into pure polymeric ACL screws may contribute to enhancing the osteogenesity of bone after full resoprption of screws,function as buffering agents that decrease the acidity of screw adjacents resulting from degradation of products, andimprovee the mechanical properties of ACL screws. In this paper, the latest bioabsorbable ACL screws which are currently available for graft fixation in orthopedic markets are discussed. A brief review of the literature regarding the physical, biological, and mechanical properties of bioabsorbable ACL screws was made. Besides,the insertion technique, various manufactured sizes, and in vitro and in vivo mechanical properties for each screw were addressed.

کلیدواژه ها:

Anterior cruciate ligament ، Reconstruction ، Bioabsorbable Screws Mechanical Properties ، biological properties

نویسندگان

J. Esmaeilzadeh

Department of Material and Chemical Engineering, Esfarayen University of Technology, Esfarayen, North Khorasan, Iran

H. Setayesh

Department of Materials and Metallurgical Engineering, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Razavi Khorasan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  •  1.     Fineberg, M. S., Zarins, B., Sherman, O. H., “Practical ...
  • 2.     Lee, J. W., Han, H. S., Han, K. J., ...
  • 3.     Zhao, D., Huang, S., Lu, F., Wang, B., Yang, ...
  • 4.     Staiger, M. P., Pietak, A. M., Huadmai, J., Dias, ...
  • 5.     Sumner, D. R., Galante, J. O., “Determinants of stress ...
  • 6.     Cutright, D. E., Hunsuck, E. E., “Tissue reaction to ...
  • 7.     Konan, S., Haddad, F. S., “A clinical review of ...
  • 8.     Lambert, K. L., “Vascularized patellar tendon graft with rigid ...
  • 9.     Kurosaka, M., Yoshiya, S., Andrish, J. T., “A biomechanical ...
  • 10.   Almazán, A., Miguel, A., Odor, A., Ibarra, J. C., ...
  • 11.   Matthews, L. S., Soffer, S. R., “Pitfalls in the ...
  • 12.   Böstman, O. M., Pihlajamäki, H. K., “Adverse tissue reactions ...
  • 13.   Bottoni, C. R., DeBerardino, T. M., Fester, E. W., ...
  • 14.   Barber, F. A., Boothby, M. H., “Bilok interference screws ...
  • 15.   Davis, K., Huser, A., Kreofsky, C., Nadler, D., Poblocki, ...
  • 16.   Watson, J. N., McQueen, P., Kim, W., Hutchinson, M. ...
  • 17.   Moisala, A. S., Järvelä, T., Paakkala, A., Paakkala, T., ...
  • 18.   Mayr, H. O., Hube, R., Bernstein, A., Seibt, A. ...
  • 19.   Arama, Y., Salmon, L. J., Sri-Ram, K., Linklater, J., ...
  • 20.   Gulick, D. T., Yoder, H. N., “Anterior cruciate ligament ...
  • 21.   Laxdal, G., Kartus, J., Eriksson, B. I., Faxen, E., ...
  • 22.   Shen, C., Jiang, S. D., Jiang, L. S., Dai, ...
  • 23.   Cheng, P., Han, P., Zhao, C., Zhang, S., Wu, ...
  • 24.   Bach, F. D., Carlier, R. Y., Elis, J. B., ...
  • 25.   Bedi, A., Kawamura, S., Ying, L., Rodeo, S. A., ...
  • 26.   Morgan, C. D., Gehrmann, R. M., Jayo, M. J., ...
  • 27.   Park, M. C., Tibone, J. E., “False magnetic resonance ...
  • 28.   Warden, W. H., Chooljian, D., Jackson, D. W., “Ten-year ...
  • 29.   Barber, F. A., Elrod, B. F., McGuire, D. A., ...
  • 30.   Fink, C., Benedetto, K. P., Hackl, W., Hoser, C., ...
  • 31.   Hackl, W., Fink, C., Benedetto, K. P., Hoser, C., ...
  • 32.   Kaeding, C., Farr, J., Kavanaugh, T., Pedroza, A., “A ...
  • 33.   Marti, C., Imhoff, A. B., Bahrs, C., Romero, J., ...
  • 34.   Myers, P., Logan, M., Stokes, A., Boyd, K., Watts, ...
  • 35.   Shen, P. H., Lien, S. B., Shen, H. C., ...
  • 36.   Drogset, J. O., Grøntvedt, T., Tegnander, A., “Endoscopic reconstruction ...
  • 37.   Papalia, R., Vasta, S., D'Adamio, S., Giacalone, A., Maffulli, ...
  • 38.   Wang, J., Xu, J., Song, B., Chow, D. H., ...
  • 39.   Chen, C. H., Lee. C. H., “Biological fixation in ...
  • 40.   Kohn, J., Abramson, S., Langer, R., “Bioresorbable and bioerodible ...
  • 41.   Urayama, H., Kanamori, T., Kimura, Y., “Microstructure and thermomechanical ...
  • 42.   Törmälä, P., “Biodegradable self-reinforced composite materials; manufacturing structure and ...
  • 43.   Rupp, S., Krauss, P. W., Fritsch, E. W., “Fixation ...
  • 44.   Caborn, D. N., Brand Jr, J. C., Nyland, J., ...
  • 45.   Chang, H. C., Nyland, J., Nawab, A., Burden, R., ...
  • 46.   Pena, F., Grøntvedt, T., Brown, G. A., Aune, A. ...
  • 47.   Kousa, P., Jarvinen, T. L., Pohjonen, T., Kannus, P., ...
  • 48.   Oh, Y. H., Namkoong, S., Strauss, E. J., Ishak, ...
  • 49.   Weimann, A., Rodieck, M., Zantop, T., Hassenpflug, J., Petersen, ...
  • 50.   Lenza, R. F. S., Jones, J. R., Vasconcelos, W. ...
  • 51.   Nakafuku, C., Takehisa, S. Y., “Glass transition and mechanical ...
  • 52.   Barber, F. A., “Poly-D, L-lactide interference screws for anterior ...
  • 53.   Esmaeilzadeh, J., Hesaraki, S., Hadavi, S. M. M., Esfandeh, ...
  • 54.   Esmaeilzadeh, J., Hesaraki, S., Hadavi, S. M. M., Ebrahimzadeh, ...
  • 55.   Martinek, V., Friederich, N. F., “Tibial and pretibial cyst ...
  • 56.   Jagodzinski, M., Scheunemann, K., Knobloch, K., Albrecht, K., Krettek, ...
  • 57.   Lajtai, G., Schmiedhuber, G., Unger, F., Aitzetmüller, G., Klein, ...
  • 58.   Weimann, A., Zantop, T., Herbort, M., Strobel, M., Petersen, ...
  • 59.   Pêgo, A. P., Grijpma, D. W., Feijen, J., “Enhanced ...
  • 60.   Farrar, D. F., Gillson, R. K., “Hydrolytic degradation of ...
  • 61.   Demirhan, M., Kilicoglu, O., Akpinar, S., Akman, S., Atalar, ...
  • 62.   Nieminen, T., Rantala, I., Hiidenheimo, I., “Biodegradable plates and ...
  • 63.   Järvelä, T., Nurmi, J. T., Paakkala, A., Moisala, A. ...
  • 64.   Barth, J., Akritopoulos, P., Graveleau, N., Barthelemy, R., Toanen, ...
  • 65.   Lee, D. W., Lee, J. W., Kim, S. B., ...
  • 66.   Hunt, J. A., Callaghan, J. T., “Polymer-hydroxyapatite composite versus ...
  • 67.   Barber, F. A., Dockery, W. D., “Long-term absorption of ...
  • 68.   Barber, F. A., Dockery, W. D., “Long-Term Degradation of ...
  • 69.   Ntagiopoulos, P. G., Demey, G., Tavernier, T., Dejour, D., ...
  • 70.   Barber, F. A., Dockery, W. D., “Biocomposite Interference Screws ...
  • 71.   Walsh, W. R., Cotton, N. J., Stephens, P., Brunelle, ...
  • 72.   Agrawal, C. M., Athanasiou, K. A., “Technique to control ...
  • 73.   Cooper, J. J., Mackie, A. T., “In vitro evaluation ...
  • 74.   Aunoble, S., Clément, D., Frayssinet, P., Harmand, M. F., ...
  • 75.   Purcell, D. B., Rudzki, J. R., Wright, R. W., ...
  • 76.   Pigni, M., Leardi, G., Battistella, F., Bernasconi, S., “Hamstring ...
  • 77.   Poandl, T., Trenka-Benthin, S., Azri-Meehan, S., Contiliano, J., Li, ...
  • 78.   Siebold, R., “Observations on Bone Tunnel Enlargement After Double-Bundle ...
  • 79.   LeGeros, R. Z., LeGeros, J. P., “Dense hydroxyapatite”, In ...
  • 80.   Bailey, C. A., Kuiper, J. H., Kelly, C. P., ...
  • 81.   Tecklenburg, K., Burkart, P., Hoser, C., Rieger, M., Fink, ...
  • 82.   Baums, M. H., Zelle, B. A., Schultz, W., Ernstberger, ...
  • 83.   Krappel, F. A., Bauer, E., Harland, U., “The migration ...
  • 84.   Wang, J., Wu, Y., Li, H., Liu, Y., Bai, ...
  • 85.   Song, B., Li, W., Chen, Z., Fu, G., Li, ...
  • 86.   Agarwal, S., Curtin, J., Duffy, B., Jaiswal, S., “Biodegradable ...
  • 87.   Zheng Y. F., Gu, X. N., Witte, F., “Biodegradable ...
  • 88.   Li, N., Zheng, Y., “Novel magnesium alloys developed for ...
  • 89.   Cheng, P., Han, P., Zhao, C., Zhang, S., Zhang, ...
  • 90.   Yao, Y., Wang, L., Li, J., Tian, S., Zhang, ...
  • 91.   Butler, D. L., “Anterior cruciate ligament: Its normal response ...
  • 92.   Rodeo, S. A., Arnoczky, S. P., Torzilli, P. A., ...
  • 93.   Beevers, D. J., “Metal vs bioabsorbable interference screws: initial ...
  • 94.   Roesler, C. R. M., Salmoria, G. V., Moré, A. ...
  • 95.   Nyland, J., Krupp, R., Greene, J., Bowles, R., Burden, ...
  • 96.   Schumacher, T. C., Tushtev, K., Wagner, U., Becker, C., ...
  • 97.   Resende, J. L., Faria, M. T. C., Las Casas, ...
  • 98.   “Arthrex BioComposite interference screws for ACL and PCL reconstruction”, ...
  • 99.   Kousa, P., Järvinen, T. L., Kannus, P., Järvinen, M., ...
  • 100.         Moré, A. D. O., Pizzolatti, A. L. A., Fancello, ...
  • نمایش کامل مراجع