A Comparative Study between Postextubation of Preterm Neonates into High-Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure
محل انتشار: مجله علمی ناباروری ایران، دوره: 12، شماره: 1
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 238
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJN-12-1_003
تاریخ نمایه سازی: 7 بهمن 1399
چکیده مقاله:
Background: For respiratory support in premature newborns, there has been a trend toward less trachealintubation, less mechanical ventilation, and more nasal respiratory support which can result in the improvement ofsuccessful extubation rate. The two commonly known types of nasal respiratory support after extubation are thenasal continuous positive airway pressure (CPAP) and high flow nasal cannula (HFNC). The current study aimed toinvestigate and compare successful extubation using HFNC and conventional nasal CPAP after a period ofendotracheal positive pressure ventilation and detect which of these two methods is better for successfulextubation with fewer side effects.Methods: This randomized controlled study was conducted on 210 preterm newborns in the neonatal intensive careunit (NICU) of Gynecology and Obstetrics Department of Qasr El Eyni Hospital. Post extubation failure rates werecompared between the two groups, namely (HFNC) and (nasal CPAP). The collected data were analyzed in SPSSsoftware (version 20).Results: Neonates who needed re-intubation within 72 h after initial extubation were higher in the HFNC group(72.7%) versus (27.3%) in the CPAP group (P-value=0.063). Moreover, 45.8% of neonates in the HFNC group neededre-intubation within 1 week of initial extubation versus 54.2% in CPAP (P-value=0.970). The mean duration ofrespiratory support using HFNC was 3.7 days, compared to 6.5 days using CPAP (P-value= 0.001). Among neonateswho suffered from nasal trauma, 90.6% of neonates belonged to the CPAP group, while 9.4% of cases belonged to theHFNC group (P-value= 0.001). Conclusion: The use of CPAP and HFNC after the extubation of preterm mechanically ventilated neonates wasstatistically equal regarding extubation failure.
کلیدواژه ها:
نویسندگان
Ramy Morsy
Armed Forces College Of Medicine, Egypt
Magda Sedky Badawy
Faculty of Medicine, Cairo University, Egypt
Reem Said
Faculty of Medicine, Cairo University, Egypt
Aliaa Ali
Faculty of Medicine, Cairo University, Egypt
Walaa Abuelhamd
Faculty of Medicine, Cairo University, Egypt
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :