SEISMIC BEARING CAPACITY OF SHALLOW FOUNDATION WITH BASE INCLINATION
سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 354
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
SEE07_319
تاریخ نمایه سازی: 29 آذر 1399
چکیده مقاله:
The determination of seismic bearing capacity for strip footings with base inclination is the aim of this paper. For this purpose, a limit equilibrium based method is used. The seismic force is considered as pseudostatic forces acting on both footing and soil and determined. To obtain the ultimate bearing capacity, an imaginary retaining wall is assumed to pass the footing wedge and the lateral earth pressure exerted on the wall in active and passive conditions are determined. The bearing capacity factors are computed for various values of soil friction angle, seismic acceleration coefficients in horizontal and vertical directions, foundation inclination. The effects of various parameters on the seismic bearing capacity factors have been studied. The results obtained from the present method are compared with other available methods, confirming the reliability of the developed method.
کلیدواژه ها:
نویسندگان
Mahmoud GHAZAVI
Professor, Civil Engineering Department,K. N. Toosi University of Technology, Tehran, Iran
Armin SALMANI
Civil Engineering Department, Islamic Azad University, Arak Branch, Arak, Iran