Influence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates
سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 523
فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJOGST-8-4_007
تاریخ نمایه سازی: 6 خرداد 1399
چکیده مقاله:
When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper time. In this study, the effect of characteristic parameters such as pipeline operational pressure (POP) and pipeline pressure drop rate (ROD) due to rupture or a major leak was experimentally investigated on DPS. 25 different conditions with the double set of the mentioned typical characteristic parameters were chosen. In each condition, the differential pressure (DP) was measured over a period of 180 s by statistically analyzing the experimental results, so 25 maximum DP values (DPSs) were obtained. The DPS rises by an increase in ROD or a decrease in POP. Because of using nitrogen gas instead of natural gas for safety reasons and the uncertainties, the DPS results can be practically applied by adding a safety factor of 15%. Finally, the diagram of DPS with respect to ROD and that of non-dimensional DPS (DOP) versus non-dimensional ROD (RTP) were provided for different POP’s.
کلیدواژه ها:
نویسندگان
Mehdi Mahmoodi
Ph.D. Candidate, Babol Noshirvani University of Technology, Mazandaran, Iran
Mofid Gorji Bandpy
Professor, Babol Noshirvani University of Technology, Mazandaran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :