Hollow Polymer Nanospheres and Fe۳O۴@TFPA-Bd-COF as a Mixture Adsorbent in Microextraction by Packed Sorbent for Extraction of BTEX Biomarkers in Urine

  • سال انتشار: 1402
  • محل انتشار: مجله تحقیقات شیمی تجزیه و تجزیه زیستی، دوره: 10، شماره: 2
  • کد COI اختصاصی: JR_ANALCH-10-2_010
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 264
دانلود فایل این مقاله

نویسندگان

Nematullah Kurd

Department of Occupational Health and Safety, School of Public Health, Behbahan Faculty of Medical Sciences, Behbahan, Iran

Abdulrahman Bahrami

Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran. Faculty of Chemistry, Bu-Ali Sina University, Hamadan, Iran

Abbas Afkhami

Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran. Faculty of Chemistry, Bu-Ali Sina University, Hamadan, Iran

Farshid Ghorbani Shahna

Department of Occupational Health and Safety, School of Public Health, Behbahan Faculty of Medical Sciences, Behbahan, Iran

MohammadJavad Assari

Department of Occupational Health and Safety, School of Public Health, Behbahan Faculty of Medical Sciences, Behbahan, Iran

Maryam Farhadian

Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamedan, Iran

چکیده

A new and fast sample preparation method was developed to extract Hippuric acid (HA), Trans,trans-muconic acid (tt-MA), Mandelic acid (MA), and m-Methylhippuric acid (m-MHA) in urine samples using Hollow polymer nanospheres (HPSs), Covalent organic frameworks (COFs), and their mixture (HPS:COF) as an adsorbent, combined with high-performance liquid chromatography-ultraviolet spectrophotometry (HPLC-UV). X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), and transmission electron microscopy (TEM) were used to study the features of the adsorbents. The effect of important factors such as temperature and pH of the sample, amount of sorbent, conditioning and washing solvents, type and volume of desorption solvent, sample volume, and the number of extraction cycles were investigated to achieve the optimal conditions with microextraction by packed sorbent (MEPS) procedure. The applicability of the proposed method was then validated in the laboratory. Finally, the target analytes in the urinary samples of gas station workers were examined. The data analysis showed that using an HPS:COF mixture improves the extraction efficiency in optimal conditions compared to the case where the COF adsorbent is used alone (extraction efficiency, ۸۱-۸۷.۵%). Also, a good linear dynamic range (۰.۱-۱۰۰۰ µg/mL for m-MHA), a low detection limit (۰.۰۲ µg/mL for tt-MA), and acceptable intra-day and inter-day precision (۱.۴-۳.۶ % and ۴.۵-۸.۹ %, respectively) were obtained under similar conditions. Overall, HPS: COF-MEPS exhibited excellent extraction efficiency (۸۵.۴-۹۳.۳%) and has the potential to replace previous methods in the biomonitoring of BTEX biomarkers in urine.

کلیدواژه ها

BTEX biomarkers, HPSs: COF adsorbent, HPLC-UV, MEPS method, Urine samples

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.