Necessity of Routine Repeat Testing of Critical Values in Various Working Shifts
محل انتشار: فصلنامه آسیب شناسی ایران، دوره: 15، شماره: 3
سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 451
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJP-15-3_003
تاریخ نمایه سازی: 31 خرداد 1399
چکیده مقاله:
Background & Objective: Accurate and timely reporting of critical values is an important issue. There is some doubt whether repeat testing of critical values would offer any advantage over single testing or not. The aim of this study was evaluation of utility of routine repeat testing of critical values in our referral center and to compare probable variations in different working shifts. Methods: Clinical results of serum Potassium, Calcium, Blood Hemoglobin and Prothrombin Time (INR: International Normalized Ratio) were evaluated for three months. Results: Totally, 178, 96, 67 and 107 consecutive critical values for Potassium, Calcium, Hemoglobin and INR were reported, respectively. In potassium and Hemoglobin 5.05% and 1.17% of retest runs exceeded the acceptable tolerance limit. All of the calcium retest results were within the acceptable limit. For INR, 21/107 retest results did not meet the acceptable tolerance limit, nine still were critical. Afternoon working run performance was significantly better than the two others. Conclusion: Our observation suggests that routine repeat of hematology and chemistry critical test result is not necessary and may adversely affect patient safety measure. However, attention should be paid to results greater than analytical measurement range and all such results should be repeated before reporting.
کلیدواژه ها:
نویسندگان
Hiva Saffar
Department of Pathology and Laboratory Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
Alireza Abdollahi
Department of Pathology and Laboratory Medicine, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
Atefe Sadat Hosseini
Department of Pathology and Laboratory Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
Mojgan Torabi Farsani
Department of Pathology and Laboratory Medicine, Tehran University of Medical Sciences, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :