Calculation and investigation of temperature distribution and melt pool size due to a moving laser heat source using the solution of hyperbolic heat transfer equation
- سال انتشار: 1389
- محل انتشار: یازدهمین کنفرانس ملی مهندسی ساخت و تولید ایران
- کد COI اختصاصی: ICME11_077
- زبان مقاله: انگلیسی
- تعداد مشاهده: 2602
نویسندگان
PhD student, Faculty of Mechanical Engineering,Semnan University
Assistant Professor, Faculty of Mechanical Engineering,Semnan University
PhD student, Faculty of Mechanical Engineering,Semnan University
PhD student, Faculty of Mechanical Engineering,Semnan University
چکیده
In this paper, the melting of a semi-infinite body as a result of a moving laser beam has been studied. Because the Fourier heat transfer equation at short times and large dimensions does not have sufficient accuracy; a non-Fourier form of heat transfer equation has been used. Due to the fact that the beam is moving in x direction, the temperature distribution and the melting pool shape are not asymmetric. As a result, the problem is a transient three-dimensional problem. Therefore, thermophysical properties such as heat conductivity coefficient, density and heat capacity are functions of temperature and material states. The enthalpy technique, used for the solution of phase change problems, has been used in an explicit finite volume form for the hyperbolic heat transfer equation. This technique has been used to calculate the transient temperature distribution in the semi-infinite body and the growth rate of the melt pool. Temporal variation of laser beam intensity in two cases of continuous and pulsatile heat flux has been considered. The latter case is a model of electrical discharge machining (EDM). In order to validate the numerical results, comparisons were made with experimental data. Finally, the results of this paper were compared with similar problem that has used the Fourier theory. The comparison shows the influence of infinite speed of heat propagation in Fourier theory on the temperature distribution and the melt pool size.کلیدواژه ها
Electrical Discharge Machining (EDM), Non-Fourier, unsteady, enthalpy technique, melt pool, radiational boundary conditionمقالات مرتبط جدید
- تحلیل مکانیزم جدید رابط بین صفحه متحرک و ثابت ربات موازی صفحه ای
- تحلیل عددی کمانش پوسته استوانهای کامپوزیت تحت فشار یکنواخت خارجی با در نظر گرفتن جدایش بین الیه ها و رشد آن با استفاده از روش المان های چسبنده
- تحلیل عددی مخزن استوانه ای جدار نازک به روش متقارن محوری و مقایسه آن با حل دقیق
- بررسی تاثیر نرخ سرد شدن بر سختی و ریز ساختار یک آلیاژ
- مروری بر کامپوزیتهای فلزی؛ ویژگیها و روشهای تولید
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.