Evaluation of the Right Heart Chambers Functions at 1-5 Years After Surgical and Device Atrial Septal Defect Closure

  • سال انتشار: 1398
  • محل انتشار: سومین کنگره جهانی قلب رضوی
  • کد COI اختصاصی: CTOG03_008
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 553
دانلود فایل این مقاله

نویسندگان

Ali Hosseinsabet

Cardiology Department, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, I.R. Iran

Mohammadreza Iri

Cardiology Department, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, I.R. Iran

Alimohammad Hajizeinali

Cardiology Department, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, I.R. Iran

Ali Hosseinsabet

Cardiology Department, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, I.R. Iran

چکیده

Background: The current treatment of secundum type atrial septal defects (ASDs) is the closure of the defect through surgery or use of percutaneous devices. The current literature lacks data on comparisons of right heart chambers functions between surgical ASD closure and percutaneous device ASD closure at follow-up durations; 1-5 years. We sought to evaluate the right atrial (RA) and right ventricular (RV) functions in patients with surgical ASD closure, patients with device ASD closure, and a control group between 1 and 5 years post procedurally. Methods: The study population comprised 30 device ASD closure patients and 30 surgical ASD closure patients, who were matched for sex, age, and procedural time, in addition to 30 control healthy subjects. The RA functions were evaluated by volumetric parameters in echocardiography and RV function was evaluated by tissue Doppler imaging. Results: The RV s’, e’ a’, E/e’ were reduced in surgical ASD closure group compared with control and device ASD closure. There was no difference regarding these markers between control and device ASD closure. RA total emptying fraction was reduced in surgical ASD closure group compared with control and device ASD closure, RA passive emptying fraction was reduced in device ASD closure group compared with control and surgical ASD closure and RA active emptying fraction was reduced in surgical ASD closure group compared with control. Conclusions: The RV systolic and diastolic function were reduced in surgical ASD closure group compared with control and device ASD closure group, RA reservoir and contraction function were reduced in surgical ASD closure group, conduit function was reduced in device ASD closure group.

کلیدواژه ها

Atrial septal defect, Right atrium, Right ventricle, Echocardiography

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.