Forming hydroxyapatite-containing Titaniacoatings on Ti6Al4V biomedical alloy via plasma electrolytic oxidation and evaluation of its corrosion behavior in simulated body fluid
- سال انتشار: 1397
- محل انتشار: اولین کنگره بین المللی مهندسی بافت و پزشکی بازساختی ایران
- کد COI اختصاصی: ITERMED01_111
- زبان مقاله: انگلیسی
- تعداد مشاهده: 335
نویسندگان
School of Metallurgy and Materials Engineering, Faculty of Engineering, University of Tehran, Iran.
School of Metallurgy and Materials Engineering, Faculty of Engineering, University of Tehran, Iran.
چکیده
Titanium and its alloys, especially Ti6Al4V, are widely used inside the human body, as artificial joints, bone staples and screws, dental implants, etc, due to their suitable corrosion resistance, high strength to weight ratio and biocompatibility. Hydroxyapatite, which is a bioactive ceramic can further improve the corrosion resistance and osseointegration of titanium. In this study, hydroxyapatite and titania, in the form of rutile, were produced on Ti6Al4V alloy by means of plasma electrolytic oxidation (PEO) process in constant voltage mode. Different electrical parameters such as frequency, duty cycle and process time were examined. Morphology, cross section and chemical composition of the coatings were evaluated by scanning electron microscope (SEM) and X-ray diffraction (XRD). Electrochemical corrosion behavior of the samples was determined by potentiodynamic polarization test in phosphate buffered saline (PBS) solution at 37 ˚C. The results showed that the sample coated under the frequency of 100 Hz, duty cycle of 40% and process time of 5 minutes had the best corrosion resistance.کلیدواژه ها
Ti6Al4V, Plasma electrolytic oxidation, Hydroxyapatite, Titania, Electrical parametersمقالات مرتبط جدید
- Non-destructive assessment of the egg quality
- Nondestructive Testing and Investigative Analysis of Rupture Stresses in Automotive Timing Belts made from CR Material Comprised of Different Number of Tensile Members
- Simulation and Testing for Tearing Occurrence in Selected Automotive Timing Belts made from Different Materials via FEM
- Detection and Sizing Fatigue Cracks in Cylindrical Metallic Structures Using a Circular-Trapezoidal ACFM Probe
- Design and construction of a welding connection crack detection robot utilizing image processing
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.