A novel MXene(Ti3AlC2)/ZnO nanocomposite modified glassy carbon electrode for rapid voltammetric detection of bisphenol A
- سال انتشار: 1397
- محل انتشار: بیستمین کنگره شیمی ایران
- کد COI اختصاصی: IRANCC20_345
- زبان مقاله: انگلیسی
- تعداد مشاهده: 644
نویسندگان
EnvironmentDepartment, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
Department of Chemistry,Faculty of Science,Graduate University of Advanced Technology, Kerman,Iran
چکیده
Bisphenol A (2,2-bis (4-hydroxyphenyl) propane, BPA) is an organic compound that widely used in the plastic industry as a monomer for producing epoxy resins and polycarbonate. BPA is ubiquitous since it can be released into the environment from bottles, packaging, and landfill leachates as well as plastics plants. BPA was nonbiodegradable and highly resistant to chemical degradation, so that the concentration of BPA in the environmental is frequently high [1]. BPA is postulated to causereproductive disorders including decrease of sperm quality in humans, birth defects due to its fetal exposure and various kinds of cancers, such as breast, testicular, andprostate cancer [2]. Therefore, a method with high sensitivity, short analysis time, low energy consumption and low cost equipment is required to detection BPA [3].Glassy carbon electrode (GCE) possess many advantages including higher electron rate transfer, wide accessible potential window, low fabrication cost. That for improve sensor electrochemical performance, glassy carbon electrodes have been modified with nanosized materials. In this paper, MXene(Ti3AlC2)/ZnO nanocomposite based electrochemical sensor was fabricated for the determination of BPA, which is very important in the clinical diagnosis. Electrochemical studies were carried out by usingcyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CHA). The results demonstrated an enhancement of the corresponding anodic currents measured after modification of the GCE. These results are beneficial for real sample analysis. The sensor worked linearly in the range of 0.1-50.0 μM and had a detection limit of 0.07 μM. The experiments illustrate that MXene(Ti3AlC2)/ZnO nanocomposite is a worthy electrode material which offers a large surface-to-volume ratio and improves the sensitivity.کلیدواژه ها
مقالات مرتبط جدید
- نقش قراردادهای هوشمند و حقوقی در بهینه سازی فرآیندهای خرید، نصب و نگهداری سیستم های فیلتراسیون در صنایع پتروشیمی
- نقش فیلترهای غشایی در صنایع نفت و گاز: اصول بازرسی و ارزیابی عملکرد سیستم های فیلتراسیون
- شبیه سازی سیالات الکتروفیلتر و داکتینگ
- سنتز و ساخت غشاهای پلی سولفون و پلی اتر سولفون با خواص و آبدوستی کنترل شده برای کاربرد در فناوری های جداسازی غشایی
- تولید عایق نسوز از پسماند تصفیه آب پالایشگاه گاز: تحولی در مدیریت پسماند و توسعه صنعتی پایدار
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.