Investigation of Over Potentials in a Short Stack with Integrated Humidifierand Water Separator Using EIS

  • سال انتشار: 1395
  • محل انتشار: دوازدهمین سمینار سالانه الکتروشیمی ایران
  • کد COI اختصاصی: ELECTROCHEMISTRY012_193
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 287
دانلود فایل این مقاله

نویسندگان

F Alizadeh

Fuel Cell Technology Research Laboratory, Malek Ashtar University of Technology, Fridonkenar, Islamic Republicof Iran

M Khorshidian

Fuel Cell Technology Research Laboratory, Malek Ashtar University of Technology, Fridonkenar, Islamic Republicof Iran

S. M. Rahgoshay

Fuel Cell Technology Research Laboratory, Malek Ashtar University of Technology, Fridonkenar, Islamic Republicof Iran

S. H. M. Saadat

Fuel Cell Technology Research Laboratory, Malek Ashtar University of Technology, Fridonkenar, Islamic Republicof Iran

چکیده

In this study, for the first time, a cascade type 4 cells stack with integrated humidifier, waterseparator and internal manifolds was designed, fabricated and tested. The diagnostic test wasconducted by EIS. The effects of dead end mode of the stack impedance spectra are studied. Theresults suggested that ohmic resistance of the single cell decreased with increasing current densitydue to the greater effect of hydration of membrane.

کلیدواژه ها

Cascade type stack, Electrochemical Impedance Spectroscopy, Dead-end Operation

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.