Voltammetric determination of tetracycline at the surface of poly (thionine)-modified carbon nanotube paste electrode
- سال انتشار: 1395
- محل انتشار: دوازدهمین سمینار سالانه الکتروشیمی ایران
- کد COI اختصاصی: ELECTROCHEMISTRY012_174
- زبان مقاله: انگلیسی
- تعداد مشاهده: 494
نویسندگان
Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran
Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran
Molecular Medicine Research Center, Rafsanjan University of Medical
Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran
چکیده
Tetracylines (TCs) produced by Streptomyces spp. are a large family of antibiotics used in humanand veterinary medicine due to their broad-spectrum activity against most Gram-positive andGram-negative bacteria (1). When tetracycline drugs are administered by laymen, as in mostcases, correct dosages and withdrawal periods are unlikely to be observed. This raises concernsthat animal tissue intended for human consumption might be contaminated with residues of TCs(2). Herein, a simple, rapid, accurate and sensitive electrochemical sensor is described for thedetermination of trace amounts of tetracycline based on a poly (thionine) film which iseffectively shuttle electrons between the analyte and the base electrode. Generally, thepreparation of conducting films by electropolymerization of a monomer which itself was a redoxmediator has been demonstrated to enhance the sensivity of the electrochemical sensor (3). In thepresent work, electropolymerization of thionine on the surface of a carbon nanotube pasteelectrode provided a chemically modified electrode which responded linearly to the concentrationof tetracycline, shifted the peak potential of tetracycline negatively and increased the peakcurrent. Electrochemical behavior of tetracycline at the surface of poly(thionine)-modified carbonnanotube paste electrode was fully characterized using cyclic voltammetry andchronoamperommetry. Moreover, the effect of different experimental parameters including pH,on the electrochemical current of tetracycline was evaluated. Under the optimized conditions, theproposed electrode showed linear dependence of peak current with the concentration of tetracycline within the range of 0.50-20.0 mM with the detection limit of 0.46 mM. Finally,tetracycline tablet and urine samples were analyzed for tetracycline with the presented methodusing standard addition. The obtained recoveries indicated the accuracy and applicability of themethod.کلیدواژه ها
Tetracycline, Poly (thionine), Carbon nanotube paste electrode, Voltammetryمقالات مرتبط جدید
- ؛ GRP-۷۸ سنتز و بهینه سازی نانوکامپوزیت آهن نیکل جهت تخلیض ایمونوگلوبولین
- نانوکامپوزیت مبتنی بر کربوکسی متیل سلولز: یک ماده زیستی امیدوار کننده برای کاربردهای زیست پزشکی
- Multi component Reaction of Isoquinoline, Dialkyl acetylenedicarboxylate, Aldehydes and Dimedone Catalyzed by Bio-CuO-NPs
- Synthesize of forward osmosis membrane with Zinc Oxide interlayer for enhanced water desalination
- Co-doping effects in CdWO۴ scintillator thin film as alpha counters: Ag and Gd case
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.