Electron microscopic comparison of corneal epithelial graft by two methods: removed mechanically and after alcohol application
- سال انتشار: 1396
- محل انتشار: نوزدهمین همایش سالانه و دومین همایش بین المللی آسیب شناسی و طب آزمایشگاه
- کد COI اختصاصی: ACPLMED19_056
- زبان مقاله: انگلیسی
- تعداد مشاهده: 398
نویسندگان
Associate professor, Department of Pathology, Shiraz University of medical Sciences, Shiraz, Iran
Poostchi Eye Research Center, Ophthalmology and Pathology Departments, Shiraz University of Medical Sciences, Shiraz, Iran
چکیده
Corneal epithelial flap used for some patients with corneal opacity. Two methods are recommended: in the first method, it is removed mechanically and in the second method epithelial corneal flap is removed after application of ethanol. The purpose of this study is to evaluate the corneal specimen of both groups by toluidine blue taining and by electron microscopic study for any microscopic or ultrastructural change. Methods In twenty eyes, the epithelial corneal flaps were removed after ethanol applicationand in nineteen eyes were removed mechanically. The specimens were fixed in glutaraldehyde 3% and embedded in resin blocks and processed for electron microscopy. One micron thickness sections were stained with toluidine blue and evaluated under a light microscope. 90-Nanometer thickness sections were put on copper grids and stained with uranium acetate and lead citrate and studied under electron microscopy. Results In the epithelial corneal flap which was removed after alcohol application, the cytoplasm of the cells shows marked dilatation of endoplasmic reticulum, cell membrane blebs, and separation of the hemidesmosomes of adjacent epithelial cells with the depth of about one-third of the length of the cells. The epithelial corneal flap which removed mechanically, tearing of hemidesmosomes between two adjacent epithelial cells were more severe with the extension of more than half of the cell length. In both groups the basement membrane under epithelial cells was intact. Conclusion Electron microscopic changes including tearing of hemidesmosome, dilatation of endoplasmic reticulum and cell membrane blebs in the mechanically removed epithelial corneal flap are more severe than in the group with alcohol application before epithelial corneal flap.کلیدواژه ها
Microscopy, Electron; Corneal Transplantation; Hemidesmosomesمقالات مرتبط جدید
- Effect of Salicylic Acid and Root Inoculation with P. indica on Cd Phytoremediation Efficiency and Degradation of Soil Fuel Oil in the Salinity Stress
- Acute Effect of Concurrent Exercise on Serum Leptin and Resistance Insulin Response in Sedentary Men
- Analysis of Incidents Recorded Data of in Kashan Fire Department During ۱۹۹۹-۲۰۱۶
- Development and Psychometric of “Public Awareness on Emergency Response in the Workplace Questionnaire”
- تجزیه و تحلیل علل ریشه ای حوادث شغلی در صنایع به کمک تکنیک های مرسوم بررسی حوادث مطالعه موردی یک حادثه منجر به فوت در پست ۲۳۰ کیلوولت
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.