Assessment of household reverse-osmosis systems in heavy metal and solute ion removal in real and synthetic samples

  • سال انتشار: 1393
  • محل انتشار: مجله پیشرفت در تحقیقات بهداشت محیط، دوره: 2، شماره: 3
  • کد COI اختصاصی: JR_JAEHR-2-3_005
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 552
دانلود فایل این مقاله

نویسندگان

Afshin Maleki

Kurdistan Environmental Health Research Centre, Kurdistan University of Medical Sciences, Sanandaj, Iran

Hiua Daraei

Kurdistan Environmental Health Research Centre, Kurdistan University of Medical Sciences, Sanandaj, Iran

Ebrahim Akhgar

Kurdistan Environmental Health Research Centre, Kurdistan University of Medical Sciences, Sanandaj, Iran

Shirzad Amini

Kurdistan Environmental Health Research Centre, Kurdistan University of Medical Sciences, Sanandaj, Iran

چکیده

In this study, the efficiency of household reverse-osmosis system (HROS) with and without neutralizer accessory was investigated in both real and synthetic samples. The real samples were collected from rural and urban public drinkingwater systems with and without primary refinery treatment. The selected areas were situated in the Kurdistan province, Iran. The HROS model RO100GPD with and without neutralizer accessory was used in all experiments to prevent effects of the membrane used, age of devices, and length of time in service. In order to assess sample quality, some more common physico-chemical analyses consisting of hardness, Ca2+, Mg2+, total dissolved solids (TDS), electrical conductivity (EC), alkalinity, Cl-, Br-, SO42-, PO43-, NO3-, NO2-, and heavy metals were performed based on standard methods. The results indicate that HROS and neutralizer accessory have significant effects on the physico-chemical properties of feed water. However, the results indicate the instability of HROS output water quality, but they verify that this instability cannot reduce the output quality. Finally, results emphasize that HROS output water meets standard levels regardless of the input water quality and application of neutralizer accessory.

کلیدواژه ها

Membranes, Drinking Water, Heavy Metals, Solute Ion, Hardness, Water Quality, Iran

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.