Effect of coagulation on different NOM fractions in spent filter backwash water
- سال انتشار: 1396
- محل انتشار: هفتمین کنفرانس بین المللی توسعه پایدار و عمران شهری
- کد COI اختصاصی: NCSDUS07_014
- زبان مقاله: انگلیسی
- تعداد مشاهده: 499
نویسندگان
Assistant Professor of Environmental Health Engineering Department, Saveh University of Medical Sciences,Social Determinants of Health Research Center, Saveh, Iran. Iran.
Department of Environmental Health Engineering, Environment Research Center, Research Institute for Primordial Prevention of Non Communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran
Department of Environmental Health Engineering, Environment Research Center, Research Institute for Primordial Prevention of Non Communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran
Department of Environmental Health Engineering, Environment Research Center, Research Institute for Primordial Prevention of Non Communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran
چکیده
Natural organic matter (NOM) is one of the most important parameters in water and wastewater reuse subjects. The aim of this study was to determine the effect of coagulation with two different coagulants (polyaluminium ferric chloride and ferric chloride) on fractional composition natural organic matter that contain in spent filter backwash water (SFBW) produced in water treatment plant. Conventional jar test apparatus was used for the coagulation procedure and the NOM was fractionated into hydrophobic, transphilic and hydrophilic fractions. NOM fractionation was conducted by DAX-8 (Supelite) and XAD-4 (Amberlite) resins. The results showed that at optimum dose of FeCl3 ( 30 mg/L) NOM fractions of the treated SFBW include 56 (± 4.6) %, 26 (± 3.7) % and 18 (± 3) % of hydrophobic, hydrophilic and transphilic fractions, respectively. These fractions for PAFCl (13 mg/L) were 68 (± 4.8) %, 22 (± 3.5) % and 10 (± 2.3) % respectively. It was concluded that the performance of PAFCl for organic matter removal was better than FeCl3. However, FeCl3was more efficient than PAFCl for the removal of hydrophobic fraction and vice versa was occurred for the removal of transphilic fraction.کلیدواژه ها
Coagulation, natural organic matter fractionation, spent filter backwash water, XAD resins, PAFCl& FeCl3مقالات مرتبط جدید
- بررسی عملکرد لرزه ای سازه های بتنی در مقابل حوادث طبیعی همچون زلزله
- بررسی جایگاه هوش مصنوعی در موفقیت مهندسی عمران
- نقش و جایگاه عمران و شهرسازی در ایجاد و توسعه گردشگری شهرهای شمالی
- واکاوی ویژگی های محیط های معماری و شهرسازی در دوران همه گیری ویروس کرونا
- بررسی ویژگی های شهر دوستدارکودک از منظر طراحی فضاهای شهری
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.