Simultaneous determination of epinephrine and acetaminophen concentrations using a modified glassy carbon electrode prepared by Graphene and NiO nanoparticles
- سال انتشار: 1394
- محل انتشار: یازدهمین سمینار سالانه الکتروشیمی ایران
- کد COI اختصاصی: ELECTROCHEMISTRY011_309
- زبان مقاله: انگلیسی
- تعداد مشاهده: 345
نویسندگان
Department of Chemistry, Faculty of Science, Yazd University, Islamic Republic of Iran
Department of Chemistry, Faculty of Science, Yazd University, Islamic Republic of Iran
Department of Chemistry, Faculty of Science, Yazd University, Islamic Republic of Iran
چکیده
Based on the outstanding properties of graphene (GR) and nickel oxide nanoparticles (NiO NPs), modified electrode was prepared by casting GR solution and then electro depositionof NiO NPs on the glassy carbon electrode (GCE) surface. GR was obtained by chemical reduction of graphite oxide (GO) and characterized by scanning electron microscope and infrared spectroscopy. The electrochemical effective surface area of two modes of electrode including theNiO/GR/GCE and NiO/GCE were calculated 0.038 and 0.029 cm2 respectively. The electro catalytic properties of NiO/GR modified glassy carbon electrode toward the oxidation of epinephrine (EP) were analyzed by cyclic voltammetry (CV) and differential pulsevoltammetry (DPV). In CV studies, in the presence of EP, NiO/GR composite modifiedelectrode shows a significantly higher current response for epinephrine oxidation. At the pH of 7.0 in a 0.1M phosphate buffer solution, the DPV anodic peak currents showed a linear relationship versus EP concentrations in the range of 1.0–100μM and 100-1800.0 μM. The detection limit of 0.84 μM with the linear detection range from 1 μM to 100μM was obtained. The modified electrode exhibits an efficient electro catalytic behavior together with wellseparated oxidation peaks for EP and acetaminophen (AC). The diffusion coefficient (D =6.56×10-5 cm2 s–1), and the kinetic parameters such as electron transfer coefficient, (α = 0.33) andcatalytic rate constant, (k´ h = 8.7 cm s-1) for EP were also determined using electrochemical approaches. Finally, the resulting sensor was used to detect EP and AC simultaneously in bloodplasma samples. The results were explained using the theory of electro catalytic reactions at chemically modified electrodesکلیدواژه ها
Graphene, Nickel oxide nanoparticles, Electro catalysis, Epinephrine, Acetaminophenمقالات مرتبط جدید
- Molecular Simulation of Water Transport through Polyamide Membrane in K+Cl- Salt Solution
- نانوکامپوزیت ها در دندانپزشکی
- Improving the characteristics of L-shaped graphene-based gas sensor using gold block on the surface
- Molecular Modelling of Gelatin Bundles for Atomistic Investigations Suggesting Two Stable Conformations
- بررسی تاثیر نانوذرات منیزیم بر جوانه زنی بذر و رشد گیاهچه بادرنجبویه Melissa officinalis
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.