Electrocatalytic determination of hydrazine and phenol using a carbon paste electrode modified with ionic liquids and nano composites
- سال انتشار: 1394
- محل انتشار: یازدهمین سمینار سالانه الکتروشیمی ایران
- کد COI اختصاصی: ELECTROCHEMISTRY011_266
- زبان مقاله: انگلیسی
- تعداد مشاهده: 350
نویسندگان
Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
Department of Chemistry, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman, Iran
چکیده
Hydrazine is highly toxic and easily absorbed by oral, breathing routes of exposure or even introduced to the skin, which mostly affect the lungs, kidney, liver and central nervous system ofliving organisms. Another important kind of pollutant is phenol, also known as carbolic acid, and widely exists in water, canned food, atmosphere and chemical productions [1]. As is well-known, nanostructure materials can decrease the overpotential of the redox process ofelectroactive species due to their large surface to volume ratio. Nanocomposite materials as a subclass of nanostructure materials have been used to fabricate a new type of chemically modified electrodes (CMEs) with rapid electron transfer kinetic [2]. In this work, a carbon paste electrode was modified with 2-(4-Oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl-hydrazinecarbothioamide, magnetic core–shell Fe3O4@SiO2/MWCNT nanocomposite and ionic liquid (n-hexyl-3-methylimidazolium hexafluoro phosphate). Square wave voltammetry (SWV) exhibits a linear dynamic range from7.0×10-8 to 5.0×10−4 M and a detection limit of 40.0 nM for hydrazine. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of hydrazine and phenol that makes it suitable for the detection of hydrazine in the presence of phenol in real samples.کلیدواژه ها
Hydrazine, Phenol, Fe3O4@SiO2/MWCNT nanocomposite, Ionic liquids, Modified electrodesمقالات مرتبط جدید
- ؛ GRP-۷۸ سنتز و بهینه سازی نانوکامپوزیت آهن نیکل جهت تخلیض ایمونوگلوبولین
- نانوکامپوزیت مبتنی بر کربوکسی متیل سلولز: یک ماده زیستی امیدوار کننده برای کاربردهای زیست پزشکی
- Multi component Reaction of Isoquinoline, Dialkyl acetylenedicarboxylate, Aldehydes and Dimedone Catalyzed by Bio-CuO-NPs
- Synthesize of forward osmosis membrane with Zinc Oxide interlayer for enhanced water desalination
- Co-doping effects in CdWO۴ scintillator thin film as alpha counters: Ag and Gd case
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.