A selective and regenerative elechtrochemical biosensor based aptamers for determination of homocysteine in biological samples

  • سال انتشار: 1394
  • محل انتشار: یازدهمین سمینار سالانه الکتروشیمی ایران
  • کد COI اختصاصی: ELECTROCHEMISTRY011_103
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 607
دانلود فایل این مقاله

نویسندگان

Jaber Saeed

Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran Young Research Society, Shahid Bahonar University of Kerman, Kerman, Iran

Mohammad Mirzaei

Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran Department of Biotechnology, Institute of Science, High Technology and Environmental Science, Graduate University of Advance Technology, Kerman, Iran

Masoud Torkzadeh-Mahani

Department of Biotechnology, Institute of Science, High Technology and Environmental Science, Graduate University of Advance Technology, Kerman, Iran

چکیده

Homocysteine (HCys) is an amino acid with a free thiol (sulphydryl) group [1]. HCys is not found in the diet but is a mediator formed in the metabolism of methionine to cysteine [2]. Inhumans, normal levels of HCys in plasma are between 5 and 16 μM [3]. In higher concentrations of HCys are related to different diseases and its cause interesting in determination of HCys [4]. An electrochemical aptasensor was adopted as an analytical platform for the selective andsensitive HCys detection using the aptamer against HCys as the recognition probe in biological samples in presence of interferences such as cysteine and methionine. The HCys aptamer used in this study is a 66-mer truncated variant of DNA aptamer with binding constant of 600 nM forHCys [5]. The conditions for the immobilization of the aptamer and for binding of HCys have been here optimized. The assay protocol of the biosensor is shown in Fig. 1. Under optimized experimental conditions, the assay was linear in the ranges from 0.2 to 10 μM for HCysDetermination. The detection limit was 0.01 μM using 3sb/m. Repeatability of the aptasensor was estimated at 1.0 μM of HCys resulted in RSD of 5.2%. The results showed this proposal is simple, regenerative and cost effective and also has a good selectivity and sensitivity for electrochemical detection of HCys in biological samples.

کلیدواژه ها

Homocysteine, Aptamer, Aptasensor, Electrochemical Biosensor, Modify Electrode

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.