Assessment of Dose Calculation Accuracy of Monaco Treatment Planning System for Effective Wedge Angle in Internal Wedged Fields using Two Different Analytical Methods

  • سال انتشار: 1404
  • محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 15، شماره: 1
  • کد COI اختصاصی: JR_JBPE-15-1_005
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 164
دانلود فایل این مقاله

نویسندگان

Ali Bahari

Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran

Seyed Salman Zakariaee

Department of Medical Physics, Faculty of Paramedical Sciences, Ilam University of Medical Sciences, Ilam, Iran

Hamed Rezaeejam

Department of Radiology Technology, School of Paramedical Sciences, Zanjan University of Medical Sciences, Zanjan, Iran

Ali Tarighatnia

Department of Medical Physics, School of Medicine, Ardabil University of Medical Sciences, Ardabil, Iran

Mikaeil Molazadeh

Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran

چکیده

Background: In radiotherapy, the accuracy of dose calculation systems plays a key role in the treatment of cancer patients.Objective: The current research aimed to evaluate the dose calculation accuracy of Monaco Treatment Planning System (TPS) in estimating the Effective Wedge Angle (EWA) using two different mathematical methods: Elekta formula and ICRU-۲۴ formula.Material and Methods: In this experimental study, EWAs for different field sizes (۵×۵, ۱۰×۱۰, ۱۵×۱۵, ۲۰×۲۰, ۲۵×۲۵, and ۳۰×۳۰ cm۲) at standard angles (۱۵°, ۳۰°, ۴۵°, and ۶۰°) were computed by the Monaco TPS using two different analytical methods. The practical EWAs were measured according to the conditions outlined in the Elekta formula and the ICRU-۲۴ formula, and these measurements were compared with the results derived from the TPS.Results: The planned and measured EWAs are consistent with the Elekta formula, and the error value was less than ±۰.۵ in all radiation fields and EWAs. In the ICRU-۲۴ formula, the maximum deviation was ±۲.۶° between the computational and practical EWAs. Conclusion: The Elekta-based analytical method demonstrates a good agreement between planned and measured EWAs, while the ICRU-۲۴ formula exhibited the greatest discrepancies.

کلیدواژه ها

Radiometry, Radiotherapy, X-rays, Internal Wedge, Effective Wedge Angle, Elekta Formula, ICRU-۲۴ Formula