Evaluation of Perkin Elmer Amorphous Silicon Electronic Portal Imaging Device for Small Photon Field Dosimetry
- سال انتشار: 1403
- محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 14، شماره: 4
- کد COI اختصاصی: JR_JBPE-14-4_003
- زبان مقاله: انگلیسی
- تعداد مشاهده: 152
نویسندگان
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
Department of Medical Physics, Faculty of Paramedical Sciences, Ilam University of Medical Sciences, Ilam, Iran
Department of Radiology Technology, School of Allied Medical Sciences, Shahid Beheshti University of Medical Science, Tehran, Iran
Radiation Oncology Department, School of Medicine, Akdeniz University, Antalya, Turkey
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
چکیده
Background: Electronic portal imaging devices (EPIDs) are applied to measure the dose and verify patients’ position.Objective: The present study aims to evaluate the performance of EPID for measuring dosimetric parameters in small photon fields.Material and Methods: In this experimental study, the output factors and beam profiles were obtained using the amorphous silicon (a-Si) EPID for square field sizes ranging from ۱×۱ to ۱۰×۱۰ cm۲ at energies ۶ and ۱۸ mega-voltage (MV). For comparison, the dosimetric parameters were measured with the pinpoint, diode, and Semiflex dosimeters. Additionally, the Monaco treatment planning system was selected to calculate the output factors and beam profiles.Results: There was a significant difference between the output factors measured using the EPID and that measured with the other dosimeters for field sizes lower than ۸×۸ cm۲. In the energy of ۶ MV, the gamma passing rates (۳%/۳ mm) between EPID and diode profile were ۹۸%, ۹۸%, ۹۵%, ۹۴%, ۹۳%, and ۹۴% for ۱×۱, ۲×۲, ۳×۳, ۴×۴, ۵×۵, and ۱۰×۱۰ cm۲, respectively. The measured penumbra width with EPID was higher compared to that measured by the diode dosimeter for both energies. Conclusion: The EPID can measure the dosimetric parameters in small photon fields, especially for beam profiles and penumbra measurements.کلیدواژه ها
Computer-Assisted, Electronic Portal Imaging Device, Photons, Radiation dosimetry, Radiotherapy Planning, Small Fieldاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.