The situation of the clarified water of Ramin Ahvaz power plant is discussed. For this purpose, thecondition of the water catchment pond, sedimentation tank and clarifier has been investigated. The results ofthe investigations show that the condition of the water catchment pond as well as the chemical injection in theclarifier stage of the Ramin power plant needs correction. In this regard, the preparation of a new watercatchment pond and the use of coagulant aid in the clarifier of Ramin Ahvaz power plant are suggested.