Numerical analysis and optimization of variable refrigeration flow systems
- سال انتشار: 1402
- محل انتشار: سومین کنفرانس بین المللی پژوهش ها و دستاوردهای نو در علوم، مهندسی و فناوری های نوین
- کد COI اختصاصی: SETBCONF03_116
- زبان مقاله: انگلیسی
- تعداد مشاهده: 152
نویسندگان
Masters’ student, Department of mechanical engineering, Faculty of Engineering,University of Science and Technology (IUST), Tehran, Iran
Assistant professor, Department of mechanical engineering, Faculty of Engineering,University of Science and Technology (IUST), Tehran, Iran
چکیده
In recent years, due to the growth of energy consumption in the world and due to the production of greenhouse gases, global warming has occurred. Therefore, the energy consumed in the cooling sector of buildings has increased significantly. However, the increase in refrigeration standards used in buildings has also been effective. Therefore, researchers are looking for new methods for air conditioning systems used in buildings that, in addition to meeting the new and strict standards of air conditioning, have less energy consumption. In this regard, one of the newly introduced methods is the use of variable flow refrigerant air conditioning systems, which has been investigated in this research. These systems can be considered the new generation of ductless multi-piece systems and one of the most efficient current air conditioning systems in the world, which allows more indoor units to be connected to each outdoor unit. Also, these systems have the possibility of simultaneous cooling and heating as well as heat recovery, thus saving energy. In this research, a typical air conditioning system has been investigated from the point of view of energy and exergy analysis. Also, for different refrigerants used in the system, the performance coefficient, exergy efficiency and exergy loss of the system have been investigated. The results show that if R۲۲ refrigerant is used, the highest performance coefficient and exergy efficiency are obtained for the system. Also, the highest amount of exergy loss is related to the compressor, then the condenser, and then the evaporator. The highest recorded COP coefficient for the system is ۴.۱.کلیدواژه ها
numerical analysis, variable refrigeration flow system, ventilation system, exergy analysis, exergy destructionمقالات مرتبط جدید
- آلاینده های نوپدید یا میکروپالستیک ها و عوارض آنها بر سلامت انسان
- Transformation in the Food Industry: The Role of Microbial Technologies in Improving Food Quality and Safety
- مروری بر ارزیابی چرخه حیات فرآیند تولید بیوروانکار از پسماند روغن خوراکی
- Measuring the pollution of underground water in Birjand plain using GIS system (research parameter: TDS in underground water)
- Accurate hourly forecasting of photovoltaic energy production using artificial intelligence algorithms: An approach based on the use of high-certainty inputs
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.