Sensitive and selective sensor for monitoring of ۴- nitrophenol levels in environmental water samples based on Poly (Biphenol / biphenoquinone - vanadium (IV)) modified electrode
- سال انتشار: 1401
- محل انتشار: کنگره توسعه علمی و فناوری دانشجویان زیست شناسی و شیمی
- کد COI اختصاصی: BCSCD01_022
- زبان مقاله: انگلیسی
- تعداد مشاهده: 205
نویسندگان
Department of Chemistry, Faculty of sciences, Ferdowsi University of Mashhad, Mashhad, Iran
Department of Chemistry, Faculty of sciences, Ferdowsi University of Mashhad, Mashhad, Iran
Inorganic Chemistry Research Laboratory, Department of Chemistry, University of Sistan and Baluchestan,P.O. Box ۹۸۱۳۵-۶۷۴, Zahedan, Iran
چکیده
In the present work, we report a new method for facile and effective synthesis of poly(biphenol/biphenoquinone-vanadium (IV)) (poly BP/BQ-VIV) for the first time. The poly BP/BQ-VIV wasapplied for modification of a carbon past electrode (CPE/ poly BP/BQ-VIV) to enhance the electro-catalyticactivity towards electro-oxidation of ۴-nitrophenol (۴-NP) molecules in solutions. The structure and theproperties of the synthesized poly BP/BQ-VIV were characterized by various techniques such as FESEM, TEM,EDX, FT-IR, UV-Vis, XPS analysis, cyclic voltammetry, differential pulse voltammetry and electrochemicalimpedance spectroscopy. The CPE/ poly BP/BQ-VIV electrochemical sensor, exhibits a well-defined anodicpeak for ۴-NP molecules at ۱.۱۸ V vs. Ag/AgCl reference electrode. Under optimum experimental conditions,the CPE/ poly BP/BQ-VIV electrochemical sensor, shows a low detection limit of ۶۰ nM, current sensitivity of۰.۹۹۶ μA μM-۱ and a linear response in the concentration range of ۰.۰۵ to ۲۰۰ μM for quantitativemeasurement of ۴-NP in aqueous solutions. The results verify that the CPE/ poly BP/BQ-VIV presents excellentreproducibility, appreciable repeatability, satisfactory stability, and high selectivity for detecting of ۴-NP intap and river water samplesکلیدواژه ها
Poly biphenol/biphenoquinone-vanadium (IV), Voltammetric determination of ۴-nitrophenol, Tap and river water samplesمقالات مرتبط جدید
- نانو ربات های پزشکی و چالش های آیند
- A review of damaged bone repair by fabricating scaffolds containing ZIF-۸
- Detection of acetaminophen in the presence of ascorbic acid using the modified electrode with Multi-Walled CarbonNanotubes/Mo(VI) complex
- بررسی خانواده های مختلف الکترون دهنده های خارجی و تاثیرات آن هادر کاتالیست های زیگلر ناتا باپایه منیزیم کلراید برای پلیمریزاسیون پروپیلن
- Nanoparticle based senotherapy of skin aging
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.