Outcomes of Temporary Hemi-Epiphysiodesis Using a New Device for The Treatment of Pediatric Valgus Knee Deformity: A Preliminary Report

  • سال انتشار: 1400
  • محل انتشار: مجله استخوان و جراحی عمومی، دوره: 9، شماره: 5
  • کد COI اختصاصی: JR_TABO-9-5_009
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 332
دانلود فایل این مقاله

نویسندگان

Mohsen Karami

Department of orthopedics, Taleghani Hospital Research Development Committee, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Adel Ebrahimpour

Department of orthopedics, Taleghani Hospital Research Development Committee, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Sohrab Keyhani

Akhtar Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Meisam Jafari Kafiabadi

Shohada Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Ramin Etemadi

Gorgan University of Medical Sciences, Gorgan, Iran

چکیده

Background: This study aimed to evaluate the efficacy of hemi-epiphysiodesis using a new device (X-plate) for thecorrection of genu valgum.Methods: In total, ۲۲ children with a total of ۳۴ pathologic knee valgus deformities underwent the procedure andwere followed up ۲۵.۳ months on average.Results: The mean time to clinical correction of genu valgum was ۱۰.۹±۲.۲ months. Furthermore, the meanpreoperative anatomic Lateral Distal Femoral Angle (aLDFA) and mechanical Tibia Femoral angle (mTFA) wereobtained at ۷۵.۱±۳.۸ and ۶±۲.۸ degrees, respectively. When clinical correction of the deformity was achieved, themean of aLDFA and mTFA corrections were determined at ۸.۹±۵.۳ and ۶.۵±۳.۲ degrees, respectively. The meanspeed of aLDFA and mTFA corrections were estimated at ۰.۸±۰.۴۵ and ۰.۶±۰.۳ degrees per month, respectively.The postoperative aLDFA and mTFA were measured at ۸۴±۴.۲ and -۰.۸±۲.۹ on average. With a mean of ۲۵.۳±۱۴.۵months at final follow-up, there were ۶ (۱۷.۶%) mild valgus knees, ۲۶ (۷۵.۵%) normal alignment knees, and only ۲(۵.۹%) mild varus knee within an acceptable clinical limit.Conclusion: Hemi-epiphysiodesis using X-plate at the distal physis of the femur is an effective and safe method forthe treatment of valgus knee deformity in children.Level of evidence: IV

کلیدواژه ها

complication, Deformity, Genu valgum, temporary hemiepiphysiodesis