STUDY ON SEISMIC ANALYSIS OF BUILDINGS USING COMBINATION OF DIFFERENT ISOLATION SYSTEMS ABSTRACT
- سال انتشار: 1394
- محل انتشار: هفتمین کنفرانس بین المللی زلزله شناسی و مهندسی زلزله
- کد COI اختصاصی: SEE07_314
- زبان مقاله: انگلیسی
- تعداد مشاهده: 393
نویسندگان
Ph.D. Student, Department of Earthquake Engineering,Science and Research Branch, Islamic Azad University, Tehran, Iran
Assistant Professor, Department of Earthquake Engineering,Science and Research Branch, Islamic Azad University, Tehran, Iran
Ph.D. Student, Department of Civil Engineering,Shahid Bahonar University of Kerman, Kerman, Iran
چکیده
The basic idea of base isolation system is to reduce the earthquake induced inertia forces by increasing the fundamental period of the structure. The aim of this study is the use of Lead rubber bearing (LRB) and friction pendulum system (FPS) as an isolation device and then to compare various parameters between fixed base condition and base isolated condition. With an aim of better including/understanding the effect of the emplacement of these devices on the response of the structures, the comparative studies were carried out in this article. The analysis is carried out by four comparative studies: the 1st and the 2nd between a fixed base structure and LRB and FPS base isolated ststems and the 3rd and 4th between a fixed base structure combination of isolation systems. The isolated structure by FPS system decreases displacements, accelerations and shear forces compared to the structure isolated by LRB. The isolated structure with Comb- 1 system decreases the displacements and shear force compared to the isolated structure with LRB system and isolated structure with Comb-2 combined system. From this study, we conclude that the use of FPS as a unique isolator is a good idea when the total cost is considered as an important thing. However, combining the FPS with a rubber-based isolator provides a good seismic isolation to the structure. In addition, thenumber and the location of the FPS at the base of a structure when is combined with a rubber-based isolator affect the response of the structure.کلیدواژه ها
Seismic Isolation, Combination Systems, Optimal Emplacement, LRB, FPSمقالات مرتبط جدید
- بهبود خواص فوتوکاتالیستی بتن خود تمیزشونده با استفاده از ترکیب اصلاح شدهنانو اکسید تیتانیوم و نانو اکسید روی
- مقایسه جداساز لرزه ای لاستیکی با هسته سربی و جداساز لرزهای پاندول اصطکاکی بر رفتارلرزهای سازه های قاب خمشی فولادی میان مرتبه دارای نامنظمی جرمی تحت اثر زلزلههای نزدیک گسل
- ارزیابی عملکرد ساختمان های نامتقارن دارای سیستم قاب خمشی بتن مسلح مجهزبه میلگردهایآلیاژ حافظه دار شکلی در برابر زلزله
- Evaluation of the behavior of concrete columns reinforced with FRP composite materialsagainst severe earthquakes
- بررسی عملکرد بتن پارچه ای، تحت بارهای ناشی از ضربه و انفجار
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.