Effect of Ambience Temperature and Electric Current Leakage on Vibration of High-Pressure Pump

سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 348

فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_SEE-4-4_011

تاریخ نمایه سازی: 6 اسفند 1398

چکیده مقاله:

In this paper, we make a brief overview of the maintenance procedures and condition monitoring methods. The WKL32 model high pressure pump made in Iran Pump Co, be evaluated by the vibration analysis and sound tests, based on the proactive maintenance procedure. We study the effect of electric current leakage which is made of using the pump chassis as the welding connection cable (NULL) and check the effect of the ambience temperature on the grease lubricant viscosity and on the corrosion of the pump’s bearings. Finally, we make appropriate cures according to the proactive maintenance procedure.

نویسندگان

Behrang Sharafi

Department of Mechanical Engineering, University of Shahid Rajaee Teacher Training University, Tehran, Iran

Valiollah Panahizadeh Rahimloo

Department of Mechanical Engineering, University of Shahid Rajaee Teacher Training University, Tehran, Iran

Amir Refahi Oskouie

Department of Mechanical Engineering, University of Shahid Rajaee Teacher Training University, Tehran, Iran