Evaluation of Right Ventricular Systolic Function by Echocardiography in Pulmonary Hypertension Associated With Congenital Heart Disease: a Cross Sectional Study

  • سال انتشار: 1393
  • محل انتشار: مجله بین المللی پزشکی رضوی، دوره: 2، شماره: 4
  • کد COI اختصاصی: JR_RIJO-2-4_008
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 296
دانلود فایل این مقاله

نویسندگان

Shahla Roodpeyma

Department of Pediatric Cardiology, Shahid Beheshti University of Medical Sciences, Tehran, IR Iran

Sima Rafieyian

Department of Pediatric Cardiology, Shahid Beheshti University of Medical Sciences, Tehran, IR Iran

Seyed Hassan Sharifi

Department of Pediatric Cardiology, Shahid Beheshti University of Medical Sciences, Tehran, IR Iran

چکیده

Background: Pulmonary arterial hypertension (PAH) is a serious complication of unrepaired congenital left-to-right shunts. The finalconsequence is right ventricular (RV) systolic dysfunction and reversal of shunt. Objectives: The aim of this study was to evaluate the clinical course and paraclinical findings in a group of patients with PAH associatedwith congenital heart disease (PAH-CHD). We also compared the results obtained by echocardiographic technique used for assessment ofRV systolic function (Tricuspid annular plane systolic excursion TAPSE) with parameters obtained by diagnostic cardiac catheterization. Patients and Methods: During a one-year period (2011-2012), all patients with confirmed diagnosis of PAH-CHD in pediatric cardiologyward of a teaching hospital enrolled in the study. They underwent through echocardiographic assessment and cardiac catheterization. Results: Forty-one patients (22 males, 19 females) with mean age of 5.5 ± 5.5 years (4 months to 18 years) entered in the study. Ventricularseptal defect (VSD) was the most common (65.8%) underlying CHD. Patients ≤ 10 years old comprised 71, 8% of subjects. The higher level ofTricuspid regurgitation (TR) was correlated with higher mean pressure of pulmonary artery (PAP), and greater resistance ratio (Rp/Rs) (P =0.001, and P = 0.044 respectively). Indexed TAPSE (TAPSE/body surface area) had a significant reverse correlation with mean PAP (P = 0.015),and Rp/RS (P = 0.002). There was a significant reverse correlation between indexed TAPSE and TR (P = 0.032). Conclusions: TAPSE is an easy echocardiographic measurement and reflected RV systolic function. Indexed TAPSE has good correlationwith hemodynamic data obtained by cardiac catheterization. TAPSE index is recommended for evaluation of RV systolic function inpediatric patients with PAH-CHD.

کلیدواژه ها

Congenital Heart Defect; Echocardiography; Pulmonary Hypertension; Right Ventricle; Tricuspid Valve

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.