Survey of performance poly aniline for removal of cadmium from drinking water

عنوان مقاله: Survey of performance poly aniline for removal of cadmium from drinking water
شناسه ملی مقاله: CBGCONF06_063
منتشر شده در ششمین کنگره ملی تحقیقات راهبردی درشیمی و مهندسی شیمی با تاکید بر فناوری های بومی ایران در سال 1398
مشخصات نویسندگان مقاله:

Malihe Saeedi - MS student of Department of Environmental Health, Faculty of Health, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran;
Giti Kashi - Associate professor, Department of Environmental Health, Faculty of Health, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran;
Hamid Reza Tashuiue - Assistant professor, Department of Eexecutive, Energy ministry, Tehran, Iran;
Mohammad Reza Khani - Associate professor, Department of Environmental Health, Faculty of Health, Associate professor, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
Rohollah Mahmoodkhany - Assistant professor, Department of Environmental Health, Faculty of Health, Associate professor, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran;

خلاصه مقاله:
Cadmium, as a very toxic heavy metal at very low levels, is a healthy and ecological concern. The goal of this applied-analytical research is to investigate of the possibility cadmium removal from urban drinking water by utilizing a batch polyaniline reactor. The variables under study involved are the pH, contact time, adsorbent amount, initial cadmium concentration, and reaction kinetics. A sample of urban drinking water is prepared containing 10-50 mg/L of cadmium. The cadmium-containing water is introduced into a batch reactor and the cadmium removal efficiency is investigated in different conditions for pH (4-9), contact time (0-90 min) and adsorbent doses (0.5-1.5 gr/dl). The average diameter in size of the polyaniline is 30 nm. The main components of the polyaniline nanoparticles are carbon and nitrogen. The best conditions for cadmium removal obtained are at pH 9, contact time 30 min, an adsorbent dose of 1 gr, and a cadmium concentration of 10 mg/L. The adsorption of cadmium on to polyaniline nanoparticles is followed a Langmuir isotherm model (R2> 0.99). The findings show that cadmium reduction efficiency is increased with increasing adsorbent dose, contact time, and decreasing cadmium concentration. This batch reactor using polyaniline nanoparticles has suitable proficiency for the cadmium removal from water.

کلمات کلیدی:
Cadmium, Langmuir isotherm model, Polyaniline nanoparticles, Sorption.