Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

  • سال انتشار: 1398
  • محل انتشار: مجله پزشکی هسته ای ایران، دوره: 27، شماره: 1
  • کد COI اختصاصی: JR_IRJNM-27-1_003
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 319
دانلود فایل این مقاله

نویسندگان

Leyla Bigdeloo

Vascular and Endovascular Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

Vahid Reza Dabbagh Kakhki

Nuclear Medicine Research Center, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

Fereshteh Ghaderi

Vascular and Endovascular Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

Lida Peyvandi

Department of Radiology, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

چکیده

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiography. Gated SPECT images were obtained with 16 frame/cardiac cycles. We derived the following diastolic indices: peak filling rate (PFR), time to PFR (TTPFR), mean filling rate in the first 1/3 of the diastole (MFR/3) and second filling rate (PFR2) due to left atrial contraction. In echocardiography we obtained the indices of ventricular filling: E wave, A wave, the E/A ratio, and the E wave deceleration time (DT) were considered. The LV isovolumic relaxation time (IVRT) was also determined. Results:There was no significant correlation between echocardiographic findings and diastolic gated SPECT findings. Using Post-Hoc One-way analysis significant difference was seen only in MFR/3 between diastolic dysfunction groups (P value=0.02). There was no significant difference in other diastolic gated SPECT variables in these groups. Conclusion: Diastolic parameters obtained from 16-frame/cardiac cycle gated SPECT didn’t correlate with echocardiographic indices.

کلیدواژه ها

Gated SPECT, Echocardiography, Diastolic function, Peak filling rate

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.