Assessment of organ absorbed dose associated with 99mTc DMSA Renal Scintigraphy of Pediatric using MIRDOSE Software

  • سال انتشار: 1397
  • محل انتشار: بیست و دومین همایش سالیانه پزشکی هسته ای ایران
  • کد COI اختصاصی: RINMMICMED22_032
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 733
دانلود فایل این مقاله

نویسندگان

Milad Najafzadeh

Department of Radiology, faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare- Abbas, Iran

Mahmoud Bagheri

Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran

Sied Kazem Razavi-Ratki

Department of Radiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

Mohammad Ali Jelodari

Nuclear Medicine Technologist, Shahid Sadoughi Hospital, Yazd, Iran

Ali Asghar Parach

Department of Medical Physics, Shahid Sadoughi of Medical Sciences, Yazd, Iran

چکیده

Background: 99mTc–Dimercaptosuccinic Acid (DMSA) as evaluation of pediatric genitourinary abnormalities has an important role in pediatric nuclear medicine. The aim of this study was to estimate organs absorbed dose for children injected by 99mTc DMSA using MIRDOSE software and hybrid planar/SPECTMethods: After injection of 99mTc-DMSA, ten children with genitourinary abnormalities underwent 3-5 planar scans and single SPECT scan (at 1 to 20 h post injection). Also for anatomical reference of patients’ organs, MRI scans were performed for each patient. A hybrid planar/SPECT method was used to plot time activity curves for obtain source organs cumulated activity and then to calculate observed doses of organs MIRDOSE software was used.Results: Mean absorbed dose due to 99mTc-DMSA in pediatric for kidneys (200 ± 160), adrenals (15.1 ±9.5), urinary bladder wall (14.7 ± 9.8), spleen (12.7 ± 7.8), gonads (12.4 ± 11.2), pancreas (10.5 ± 6.2), gall bladder wall (9.8 ± 5.7), micro Sivert per MegaBequrel, respectively. Also, the mean effective doses were 10.01 ± 6.03 μSv/MBq.Conclusion: The difference between the radiation doses received by the various organs of the patients caused by different amounts of radiopharmaceutical uptake in organs for different patients. Image quantities practical method using planar/SPECT hybrid method can be utilized with acceptable accuracy in determination of cumulative activity.

کلیدواژه ها

Internal Absorbed dose, Combined SPECT/planar method, MIRDOSE software, Cumulated activity