Selective preconcentration of trace amount of Lead using a novel surface imprinting polymer based on graphene oxide-mesoporous silica nanosheets in Fish samples
- سال انتشار: 1398
- محل انتشار: نهمین سمینار ملی شیمی و محیط زیست ایران
- کد COI اختصاصی: NSCEI09_065
- زبان مقاله: انگلیسی
- تعداد مشاهده: 518
نویسندگان
Department of Chemistry, Islamic Azad University, Ilam branch, Ilam, Iran
Department of Chemistry, Islamic Azad University, Ilam branch, Ilam, Iran
چکیده
The safe concentration levels of toxic heavy metals in the environment have been seriously increased during the last decades due to human and industrial activities [1]. The long term exposure of heavy metals has a severe detrimental affect on human health [2]. Lead is one of the most toxic elements and possesses bio-accumulative effect, that‟s why it is called environmental priority pollutants. Hence it is very important to monitor the levels of lead in environments [3]. Sol-gel process is considered as a promising technique, which consists of the hydrolysis and co-condensation of organosilanes. Mesoporous hybrid functionalized solids can be obtained by adding cross-linker into sol-gel process [4]. Adsorbents prepared by sol-gel process show some advantages, such as high mechanical strength, excellent chemical and thermal stabilities, rigid pore structure and high adsorption capacity, owing to large internal surface area and volume. It is very urgent to develop a preparation method of adsorbent with not only high adsorption performance but also green and environmentally friendly synthesis procedure. In this work, a new and green Pb(II) ion-imprinted polymer was prepared by sol-gel process for removal of Pb(II) ions from aqueous solution. In this research, nanosheets of graphene oxide on mesoprose silica with aminoimide ligand were used for trace separating and preconcentrating of lead. For synthesis of this nano-adsorbent, an amine-imide ligand was synthesized, and certain amount of the ligand and lead nitrate dissolved in a mixture of water / methanol (4: 1) and in the presence of ammonium sulfate as a primer and EGDMA as a cross linker. Prepared polymers were characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), and Brunauer, Emmett and Teller (BET). Some main factor such as the interaction time, pH, and amount of adsorbent were selected and their optimum conditions were determined by the experimental design. The optimum condition obtained when 14.46 mg of adsorbent was used at pH value of 6.9 for 32 min. Using a new conventional polymer, measurements of lead II levels in fish samples such as salmon, sardines, yolk fish and tuna fish have been successfully evaluated using a flame atomic absorption spectroscopy.کلیدواژه ها
مقالات مرتبط جدید
- بررسی فنی و اقتصادی پروژههای ژئوتکنیکی بهسازی خاک در خاک های ماسهای چالو س
- عدالت محیطزیستی در سکونتگاههای حاشیهای: سنجش شاخص های پایداری در سکونتگاههای غیررسمی منطقه ۲ مشهد
- عوامل موثر بر ریسک های منابع انسانی در پروژه های عمرانی
- فرصتهای توسعه فضای تفریحی و گردشگری شهر مشهد
- از سرگیری الگوهای معماری بومی با استفاده از هوش مصنوعی: یک بررسی جامع
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.