A Novel Cooling/Heating Assisted Switchable Solvent Based Microextraction Process: Application for Determination of Phthalate Esters in Water Samples
- سال انتشار: 1398
- محل انتشار: نهمین سمینار ملی شیمی و محیط زیست ایران
- کد COI اختصاصی: NSCEI09_048
- زبان مقاله: انگلیسی
- تعداد مشاهده: 574
نویسندگان
Razi Vaccine and Serum Research Institute, Agricultural Research, Education and Extension Organization (AREEO), Karaj, Iran
Department of Chemistry, Faculty of Science, University of Zabol, P.O. Box ۹۸۶۱۵-۵۳۸, Zabol, Iran
Department of Chemistry, Faculty of Science, University of Zabol, P.O. Box ۹۸۶۱۵-۵۳۸, Zabol, Iran
چکیده
A Switchable hydrophilicity Solvent (SHS) is a solvent that can reversibly switch between one forms that is miscible with water to another that forms a biphasic mixture with water. In this work, A novel temperature controlled SHS based microextraction method has been developed for the extraction and preconcentration of four phthalate esters (PAEs) from water samples prior to GC-MS analysis. For the first time, the effect of temperature in the switching of extracting solvent has been studied and the application of cooling/heating processes instead of addition of chemicals in the switchable solvent based microextraction has been used for PAEs extraction. Several parameters including solvent type, solvent volume, temperature of dissolution, temperature of separation, and salt addition are optimized. A theoretical study also has been provided to reveal the effect of cooling/heating effects on the homogenization and separation of phases. The proposed method provided some advantages such as simplicity, using low volumes of inexpensive and less hazardous reagents, rapid extraction and reduced analysis time. For the developed method, LODs and LOQs were obtained in the ranges of 0.03-0.06 and 0.1-0.2 μgL−1 respectively. Also, calibration curves were linear within the range of 0.2-100 μgL−1 for dimethyl phthalate and dibutyl phthalate, and 0.1-100 μgL−1 for diethyl phthalate and dioctyl phthalate. Enrichment factors (EFs) were found to be in the range of 110.9-116.3. The proposed method was applied for the analysis of PAEs in real water samples.کلیدواژه ها
مقالات مرتبط جدید
- استفاده از مواد دوست دار محیطزیست بهعنوان جایگزین برای صنعت بستهبندی مواد غذایی
- مروری بر کاربرد چارچوبهای فلزی-آلی در جذب دیاکسید کربن
- کنترل بهینه یک مدل دینامیکی امکانات و تسهیلات گردشگری در جهت توسعه پایدار مبتنی بر تاثیرات عوامل محیطی
- بررسی موانع پیاده سازی استانداردهایISO با تاکید بر مدیریت سبز با استفاده از شبکههای عصبی عمیق کانولوشن
- استخراج رمزارز و چالش های آلودگی محیط زیست
اطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.