Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

سال انتشار: 1393
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 285

فایل این مقاله در 5 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JDMT-3-3_005

تاریخ نمایه سازی: 20 مهر 1398

چکیده مقاله:

Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group was just brackets as a control group. Each group had five samples. Four brackets were then connected to each wire by elastic bands made from electrochemically neutral material. The samples were immersed into capped containers of Fusayama-Meyer artificial saliva. After six weeks, the released nickel ions were quantified via ion absorption technique. The mean and the standard deviation of all four groups were calculated and the data were compared together with Kruskal-Wallis non-parametric statistical test. Results: The highest concentration of released nickel ions was for bracket+ steel archwire and the least for the bracket without archwire. Conclusion: There were not significant differences among experimental groups, so it could be concluded that galvanic corrosion would not be a serious consideration through orthodontic treatment.  

نویسندگان

Farzin Heravi

Dental Materials Research Center, Department of Orthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran

Nima Mokhber

Department of Orthodontics, Academic Center of Education, Culture and Research, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran

Elnaz Shayan

Department of Endodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Bakhtari A, Bradley TG, Lobb WK, Berzins DW. Galvanic corrosion ...
  • Karov J, Hinberg I. Galvanic corrosion of selected dental alloys. ...
  • Daems J, Celis JP, Willems G. Morphological characterization of as-received ...
  • Von Fraunhofer JA. Corrosion of orthodontic devices. Semin Orthod 1997;3:198-205. ...
  • House K, Sernetz F, Dymock D, Sandy JR, Ireland AJ. ...
  • Regis S Jr, Soares P, Camargo ES, Guariza Filho O, ...
  • Ortiz AJ, Fernández E, Vicente A, Calvo JL, Ortiz C. ...
  • Kolokitha OE, Chatzistavrou E. Allergic reactions to nickel-containing orthodontic appliances: ...
  • Pazzini CA, Júnior GO, Marques LS, Pereira CV, Pereira LJ. ...
  • Genelhu MC, Marigo M, Alves-Oliveira LF, Malaquias LC, Gomez RS. ...
  • Kusy RP. Clinical response to allergies in patients. Am J ...
  • Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness ...
  • Kao CT, Huang TH. Variations in surface characteristics and corrosion ...
  • Gioka C, Eliades T. Materials-induced variation in the torque expression ...
  • Yokoyama K, Hamada K, Moriyama K, Asaoka K. Degradation and ...
  • Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness ...
  • Kusy RP. Types of corrosion in removable appliances: annotated cases ...
  • Eliades T. Orthodontic materials research and applications: part 2. Current ...
  • Von Fraunhofer JA. Corrosion of orthodontic devices. Semin Orthod 1997;3:198-205. ...
  • Eliades T, Athanasiou AE. In vivo aging of orthodontic alloys: ...
  • Mikulewicz M, Chojnacka K, Woźniak B, Downarowicz P. Release of ...
  • Eliades T, Pratsinis H, Kletsas D, Eliades G, Makou M. ...
  • Petoumeno E, Kislyuk M, Hoederath H, Keilig L, Bourauel C, ...
  • Sahoo N, Kailasam V, Padmanabhan S, Chitharanjan AB. In-vivo evaluation ...
  • Khoury ES, Abboud M, Bassil-Nassif N, Bouserhal J. Effect of ...
  • Li X, Wang J, Han EH, Ke W. Influence of ...
  • Schiff N, Dalard F, Lissac M, Morgon L, Grosgogeat B. ...
  • Iijima M, Endo K, Yuasa T, et al. Galvanic corrosion ...
  • Siargos B, Bradley TG, Darabara M, Papadimitriou G, Zinelis S. ...
  • Schiff N, Boinet M, Morgon L, Lissac M, Dalard F, ...
  • Darabara MS, Bourithis LI, Zinelis S, Papadimitriou GD. Metallurgical characterization, ...
  • Platt JA, Guzman A, Zuccari A, Thornburg DW, Rhodes BF, ...
  • Venugopalan R, Lucas LC. Evaluation of restorative an implant alloys ...
  • Karov J, Hinberg I. Galvanic corrosion of selected dental alloys. ...
  • Lim S, Takada Y, Kim K, Okuno O. Ions released ...
  • Widu F, Drescher D, Junker R, Bourauel C. Corrosion and ...
  • Katić V, Curković HO, Semenski D, Baršić G, Marušić K, ...
  • Oshida Y, Sachdeva RCL, Miyazaki S. Microanalytical characterization and surface ...
  • نمایش کامل مراجع