Temperature Mapping Using Ultrasound Digital Images

  • سال انتشار: 1384
  • محل انتشار: مجله فیزیک پزشکی ایران، دوره: 2، شماره: 3
  • کد COI اختصاصی: JR_IJMP-2-3_008
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 313
دانلود فایل این مقاله

نویسندگان

A. Nurouzi

M.Sc. in Medical Physics, Tehran University of Medical Sciences, Tehran, Iran.

M. J. Abolhasani

Assistant Professor, Physics and Biomedical Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran. Research Center for Science & Technology in Medicine, Imam Khomeini Hospital, Tehran, Iran.

A. Takavar

Professor, Physics and Biomedical Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran.

M. A. Oghabian

Assistant Professor, Physics and Biomedical Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran. Research Center for Science & Technology in Medicine, Imam Khomeini Hospital, Tehran, Iran.

چکیده

Introduction:  The  success  of  hyperthermia  depends  on  the  accuracy  of  the  temperature  monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes  were determined by computing the speckle displacement in the ultrasound digital images. Speckle  tracking algorithm was used to compute the displacement.  Materials and Methods: The experiment was performed on Tissue Mimicking (TM) phantoms.  The imaging probe used was a commercial type linear array operating at 10 MHz. The speckle  displacement  along  the  axial  direction  was  computed  using  Speckle  Tracking  method  and  the  temperature  changes  were  obtained  from  the  displacement  data.  Additionally,  the  temperature  changes during the heating were invasively measured by NTC thermistors. The results of the two  methods were compared against each other.   Results:  There  was  a  good  agreement  between  the  Ultrasonic  temperature  estimation  and  the  measurements made by the thermistors. The maximum error and the standard deviation obtained  were 0.53 and 0.2°C, respectively.   Discussion  and  Conclusion:  Speckle  tracking  algorithm  is  capable  of  extracting  motion  information from both the ultrasounic digital images and radiofrequency (RF) echo signals. The  temperature changes can be obtained from the displacement data. 

کلیدواژه ها

Ultrasound, Speed of sound, Speckle tracking, Cross-correlation, Temperature Monitoring

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.