Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT

سال انتشار: 1389
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 371

فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-7-3_006

تاریخ نمایه سازی: 20 مهر 1398

چکیده مقاله:

Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident angle. Material and Methods: To investigate the spatial resolution and the FOV in VRX CT, we used the numerical parameters of an actual VRX CT scanner. The effects of decreasing the focal spot size and optimizing magnification on the spatial resolution and the FOV of the system were studied theoretically. Results: The focal spot size was found to greatly limit the spatial resolution of the VRX CT at the small incident angles. By decreasing the focal spot size, the spatial resolution was comparatively improved. Optimization of the system magnification without decreasing the focal spot size could greatly increase the spatial resolution of the system. After optimization of magnification, the FOV of the system decreased significantly. Discussion and Conclusion: The spatial resolution of the system after optimizing the magnification increased from 7.5 to more than 35 cycles/mm and also the effect of the focal spot no longer limited the spatial resolution at incident angles smaller than 13˚. The disadvantage of optimization of magnification was a great decrease in the FOV of the system. The optimization of magnification has the reverse effect on the spatial resolution and the FOV of the system so at each incident angle, according to the importance of spatial resolution or FOV, the system magnification can be set to lead to the desirable condition.

کلیدواژه ها:

Field of View ، Spatial resolution ، System Magnification ، Variable resolution X-ray (VRX) CT

نویسندگان

Hossein Arabi

M.Sc. Student, Radiation Medicine Dept., Shahid Beheshti University, Tehran, Iran.

Alireza Kamali Asl

Assistant Professor, Nuclear Engineering Dept., Shahid Beheshti University, Tehran, Iran.

Seyed Mahmood Reza Aghamiri

Associate Professor, Nuclear Engineering Dept., Shahid Beheshti University, Tehran, Iran.