Effect of Average Annual Mean Serum Ferritin Levels on QTc Interval and QTc Dispersion in Beta-Thalassemia Major
- سال انتشار: 1396
- محل انتشار: مجله بین المللی کودکان، دوره: 5، شماره: 8
- کد COI اختصاصی: JR_INJPM-5-8_002
- زبان مقاله: انگلیسی
- تعداد مشاهده: 449
نویسندگان
Assistant Professor, Department of Pediatric Cardiology, Faculty of Medicine, Arak University of Medical Sciences, Arak, Iran.
Assistant Professor, Department of Cardiac Surgery, Faculty of Medicine, Arak University of Medical Sciences, Arak, Iran.
Assistant Professor, Department of Pediatric Hematology and Oncology, Faculty of Medicine, Arak University of Medical Sciences, Arak, Iran.
Master of Sciences in Biostatistics, Department of Biostatistics, Faculty of Medicine, Arak University of Medical Sciences, Arak, Iran.
چکیده
Background There is evidence indicating impaired cardiomyocytic contractility, delayed electrical conduction and increased electrophysiological heterogeneities due to iron toxicity in beta-thalassemia major patients. In the present study, we compared the electrocardiographic and echocardiographic features of beta-thalassemia major patients with a healthy control group. Materials and Methods The average annual serum ferritin levels of fifty beta-thalassemia major patients were assessed. For each patient, corrected QT (QTc) intervals and QTc dispersions (QTcd) were calculated and V1S and V5R were measured. All subjects underwent two-dimensional M-mode echocardiography and Doppler study and were compared with 50 healthy subjects as a control group. Results QTc interval and dispersion were significantly higher in beta-thalassemia major patients (P= 0.001). The mean V5R (20.04 ± 4.34 vs. 17.14 ± 2.55 mm) and V1S (10.24 ± 2.62 vs. 7.83 ± 0.38 mm) showed considerably higher mean values in patients in comparison with control group.Peak mitral inflow velocity at early diastole and early to late ratio in the case- group was markedly higher(P< 0.001), whereas, early deceleration time (P=0.01) and Isovolumic relaxation time (IVRT) (P=0.001), were meaningfully lower than the control group. There was positive correlation between age and QTc (r= 0.831, P=0.001) and QTc dispersion (r= 0.710, P=0.001) and negative correlation between serum level of ferritin and V5R (r= -0.271, P= 0.05). Conclusion Measurement of the QTc interval and dispersion can be used for early detection of cardiac involvement, especially in asymptomatic beta-thalassemia patients with ferritin levels higher than 2,500 ng/dl.کلیدواژه ها
Arrhythmia, Beta-thalassemia major, Ferritinاطلاعات بیشتر در مورد COI
COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.
کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.