MG-63 cell behavior on Ti6Al4V implant surfaces modified by pulsed Nd-YAG laser

سال انتشار: 1397
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 430

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ITERMED01_030

تاریخ نمایه سازی: 7 مرداد 1398

چکیده مقاله:

Introduction Titanium alloys are commonly used in orthopedic devices due to their good corrosion resistance, high specific strength and excellent biological response. Surface modification of these alloys causes better osseointegration of bone. Objectives In this study, by use of a pulsed Nd-YAG laser with different frequencies, the surface topography of Ti6Al4V alloy was changed. Methods In order to investigate the effect of this type of texturing on the cell behavior, MG-63 osteoblast cells were cultured on the modified surfaces and control samples. Furthermore, MTT cytotoxicity assay and cell attachment assay were performed. Results The results revealed that the viability and morphology of cells in treated samples were better than the controls. The best result was obtained from the specimen with the highest roughness index

نویسندگان

Kimia Rafiee

Department of Materials Engineering, Tarbiat Modares University, Tehran, Iran

Homam Naffakh Moosavy

Department of Materials Engineering, Tarbiat Modares University, Tehran, Iran

Elnaz Tamjid

Department of Nano-biotechnology, Tarbiat Modares University, Tehran, Iran