Detection of Lead and Cadmium using Biosensor Expressing Luciferase Reporting Gene in Aquatic Environment

  • سال انتشار: 1398
  • محل انتشار: سیزدهمین کنگره ی پژوهشی سالیانه دانشجویان علوم پزشکی شرق کشور
  • کد COI اختصاصی: MSEMSMED13_112
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 546
دانلود فایل این مقاله

نویسندگان

Zeinab Sadat Hosseini

Student research committee, Islamic Azad university, Mashhad Branch, Mashhad, Iran

Mahsa farjami

Department of Medical Biochemistry, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.

چکیده

Background and Objective: Bacterial biosensors refer to bacterial cells that have been genetically engineered to produce a measurable signal in response to a specific chemical or physical agent in their environment. Bacterial biosensors for detection of heavy metals typically composed of a promoter (responsible for sensing or interacting with the target analyte) fused to a reporter gene (responsible for generation of the detectable biological signal). Biosensor has great potential for detection of environmental contaminants. Method and material: Two biosensor gene constructs were engineered by using lead responsive elements from plasmid pMOL30 of Ralstonia metallidurans CH34 strain (pbr promoter and pbrR as a regulatory gene) and lead and cadmium responsive elements from pI258 plasmid of Staphylococcus aureus (cadA promoter and cadC as a regulatory gene) to control the expression of the firfly luciferase gene, which functioned as the reporter. They were called pGL3-luc/pbr-Biosensor and pGL3-luc/Cad-Biosensor respectively. Escherichia coli DH5α is the host organism. Results: pGL3-luc/pbr-Biosensor is reported to be able to detect Pb+2 in the range of 1–100 μM by expressing firefly luciferase and not expressing reporter in present of other metals such as Sn+2, Ni+2, Cd+2. Moreover, this biosensor is 50 times more sensitive compared to the previous biosensors constructed by Chakraborty. Conclusion: Use of these bacterial biosensors has many benefits such as measuring the available concentrations of heavy metals, saving time and cost and ease of use.

کلیدواژه ها

bacterial biosensor, pbr promoter, cadA promoter, heavy metals, contamination, detection, lucifer

مقالات مرتبط جدید

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.