Comparison of Restricted Fluid Volume with Standard Fluid Volume in Management of Transient Tachypnea of the Newborns: A Randomized Controlled Trial

  • سال انتشار: 1397
  • محل انتشار: مجله بین المللی کودکان، دوره: 6، شماره: 9
  • کد COI اختصاصی: JR_INJPM-6-9_015
  • زبان مقاله: انگلیسی
  • تعداد مشاهده: 431
دانلود فایل این مقاله

نویسندگان

Fatemeh Eghbalian

Department of Pediatrics, Hamadan University of Medical Sciences, Hamadan, IR Iran.

Mohammad Kazem Sabzehei

Department of Pediatrics, Hamadan University of Medical Sciences, Hamadan, IR Iran.

Nezamedin Emamzadeh

Department of Pediatrics, Hamadan University of Medical Sciences, Hamadan, IR Iran.

Maryam Shokouhi

Department of Pediatrics, Hamadan University of Medical Sciences, Hamadan, IR Iran.

چکیده

Background Transient tachypnea of the newborn (TTN) is one of the most common neonatal respiratory disease and its symptoms usually begins in the first few hours after birth. The volume of fluid intake according to the neonate s conditions varies. We aimed to compare the restricted fluids volume with standard fluids volume in treatment of neonates with TTN. Materials and Methods: This clinical trial was performed on 80 neonates with a diagnosis of TTN admitted in the Neonatal intensive care unit (NICU) of Fatemiyeh Hospital and Beasat Hospital of Hamadan Medical University in Iran. Patients were randomly divided to standard fluids volume (control = 40), and restricted fluids volume treatment groups (case = 40). The hospitalization duration, oxygen therapy duration as well as the number of days need for oxygen with hood; Nasal continuous positive airway pressure (NCPAP), and mechanical ventilation therapy was recorded. After data collection, the data were statistically analyzed via SPSS software (version 21.0). Results: The subjects were 30 (37.5%) females and 50 (62.5%) males (62.5%) with an average gestational age of 38.12(±1.07) weeks.The main aim from this interventional study was effect of restricted fluidtherapy on management of TTN in NICU section. The hospitalization duration, oxygen therapy duration and need for oxygen therapy with hood in the intervention group were significantly lower than the control group (P< 0.05), but need for mechanical ventilation and need for NCPAP were not significantly different between the two groups (P> 0.05). Conclusion TTN treatment with restricted fluids volume, compared with standard volume of fluids, significantly reduces the need for respiratory supports as well as the duration of hospitalization in the NICU section.

کلیدواژه ها

Restricted fluids volume, Standard fluids volume, Transient tachycardia of the newborn

اطلاعات بیشتر در مورد COI

COI مخفف عبارت CIVILICA Object Identifier به معنی شناسه سیویلیکا برای اسناد است. COI کدی است که مطابق محل انتشار، به مقالات کنفرانسها و ژورنالهای داخل کشور به هنگام نمایه سازی بر روی پایگاه استنادی سیویلیکا اختصاص می یابد.

کد COI به مفهوم کد ملی اسناد نمایه شده در سیویلیکا است و کدی یکتا و ثابت است و به همین دلیل همواره قابلیت استناد و پیگیری دارد.